4 - 35
4 Safety Function Blocks
NX-series Safety Control Unit Instructions Reference Manual (Z931)
4
SF
_EnableSw
itch
FB-specific State Codes (No Error)
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
0000
0
Idle
The FB is disabled (default).
Ready
= FALSE
S_EnableSwitchOut
= FALSE
Error
= FALSE
8004
32772
Basic Operation Mode
Safe operation mode is OFF.
Ready
= TRUE
S_EnableSwitchOut
= FALSE
Error
= FALSE
8005
32773
Safe Operation Mode
Safe operation mode is ON.
Ready
= TRUE
S_EnableSwitchOut
= FALSE
Error
= FALSE
8006
32774
Position 1
Safe operation mode is ON and the enable switch
is in position 1.
Ready
= TRUE
S_EnableSwitchOut
= FALSE
Error
= FALSE
8007
32775
Position 3
Safe operation mode is ON and the enable switch
is in position 3.
Ready
= TRUE
S_EnableSwitchOut
= FALSE
Error
= FALSE
8000
32768
Position 2
Safe operation mode is ON and the enable switch
is in position 2.
Ready
= TRUE
S_EnableSwitchOut
= TRUE
Error
= FALSE
Summary of Contents for NX-SL series
Page 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 269: ......