2 - 61
2 Standard Functions
NX-series Safety Control Unit Instructions Reference Manual (Z931)
Math In
struc
tion
s
2
MU
L
You cannot include more than one duration in the values to multiply.
To multiply a duration, set a duration for
In1
and
Out
and set integers for
In2
to
InN
.
• When multiplying integers, the data types of
In1
to
InN
and
Out
can be different. If they are different,
calculations are performed with the data type that includes the range of all of the data types. For
example, if
In1
is INT data and
In2
is DINT data, calculations are performed with DINT data. There-
fore, multiplication result
Out
will be DINT data.
• If you use duration data for the data to multiply, use duration data for one of
In1
to
InN
and for
Out
.
• The input condition depends on whether the output is safety data or standard data. If the condition is
not met, a building error will occur. If you set a safety data type variable for the output terminal, set
safety data type variables for all of the input terminals.
• If you set a standard data type variable for the output terminal, you can set either a safety data type
variable or a standard data type variable for the input terminal.
• If you set a safety data type variable for the output terminal, set safety data type variables for all of
the input terminals.
• If you set a standard data type variable for the output terminal, you can set either a safety data type
variable or a standard data type variable for the input terminal.
*3. For example, if the value of
In1
is T#24d20h31m23s649ms and the value of
In2
is INT#2, the value of the mul-
tiplication result is T#49d17h2m47s298ms. However, the maximum value of TIME is the same as for DWORD
(4294967295), so the multiplication result will be the value that can be expressed with 32 bits, i.e., T#2ms.
Additional Information
Precautions for Correct Use
Summary of Contents for NX-SL series
Page 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 269: ......