![background image](http://html1.mh-extra.com/html/omron/nx-sl-series/nx-sl-series_instruction-and-reference-manual_742411207.webp)
4 - 77
4 Safety Function Blocks
NX-series Safety Control Unit Instructions Reference Manual (Z931)
4
SF
_Muting
P
a
r
C002
49154
Reset Error 2
When the Wait for Reset state was entered, an
undetected change to TRUE in the
Reset
input
was detected.
Ready
= TRUE
S_AOPD_Out
= FALSE
S_MutingActive
= FALSE
Error
= TRUE
C003
49155
Error Muting lamp
An error was detected in the muting lamp.
Ready
= TRUE
S_AOPD_Out
= FALSE
S_MutingActive
= FALSE
Error
= TRUE
CYx4
---
*1
Error Muting sequence
A muting sequence error was detected in state
8000, 8011, 8311, 8012, 8021, 8014, 8314, 8122,
8422, 8121, 8112, 8114, or 8414.
Ready
= TRUE
S_AOPD_Out
= FALSE
S_MutingActive
= FALSE
Error
= TRUE
Y = Sequence state (forward direction: 6 states,
backward direction: 6 states)
C0x4 = Error occurred in state 8000.
C1x4 = Error occurred in forward direction in
state 8011.
C2x4 = Error occurred in forward direction in
state 8311.
C3x4 = Error occurred in forward direction in
state 8012.
C4x4 = Error occurred in forward direction in
state 8014.
C5x4 = Error occurred in forward direction in
state 8314.
C6x4 = Error occurred in forward direction in
state 8021.
C7x4 = Error occurred in backward direction in
state 8122.
C8x4 = Error occurred in backward direction in
state 8422.
C9x4 = Error occurred in backward direction in
state 8121.
CAx4 = Error occurred in backward direction in
state 8114.
CBx4 = Error occurred in backward direction in
state 8414.
CCx4 = Error occurred in backward direction in
state 8112.
CFx4 =
MutingEnable
was not detected.
x = Sensor status when the error occurred (4 bits:
LSB = MS_11; MS_12; MS_21; MSB = MS_22).
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
Summary of Contents for NX-SL series
Page 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 269: ......