![background image](http://html1.mh-extra.com/html/omron/nx-sl-series/nx-sl-series_instruction-and-reference-manual_742411208.webp)
4 Safety Function Blocks
4 - 78
NX-series Safety Control Unit Instructions Reference Manual (Z931)
FB-specific State Codes (No Error)
C005
49157
Parameter Error
The value of
DiscTime11_12, DiscTime21_22
or
MaxMutingTime
is outside of the valid range.
Ready
= TRUE
S_AOPD_Out
= FALSE
S_MutingActive
= FALSE
Error
= TRUE
C006
49158
Error Timer MaxMuting
Timing error: The muting operation time while
S_MutingActive
= TRUE exceeded
MaxMuting-
Time
.
Ready
= TRUE
S_AOPD_Out
= FALSE
S_MutingActive
= FALSE
Error
= TRUE
C007
49159
Error Timer MS11_12
Timing error: Discrepancy time between
MutingSwitch11
and
MutingSwitch12
exceeded
DiscTime11_12.
Ready
= TRUE
S_AOPD_Out
= FALSE
S_MutingActive
= FALSE
Error
= TRUE
C008
49160
Error Timer MS21_22
Timing error: Discrepancy time between
MutingSwitch21
and
MutingSwitch22
exceeded
DiscTime21_22.
Ready
= TRUE
S_AOPD_Out
= FALSE
S_MutingActive
= FALSE
Error
= TRUE
*1. Find the DiagCode hexadecimal value with the information given in
Status description and output results
and then convert
it to the DiagCode decimal value.
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
0000
0
Idle
The FB is disabled (default).
Ready
= FALSE
S_AOPD_Out
= FALSE
S_MutingActive
= FALSE
Error
= FALSE
8000
32768
AOPD Free
Muting is disabled but the control input from
AOPD is active. If the muting timer is operating,
it stops.
Ready
= TRUE
S_AOPD_Out
= TRUE
S_MutingActive
= FALSE
Error
= FALSE
DiagCode (hexadecimal)
DiagCode
(decimal)
Status name
Status description and output results
Summary of Contents for NX-SL series
Page 8: ...CONTENTS 6 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 28: ...Sections in this Manual 26 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 98: ...2 Standard Functions 2 64 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 104: ...2 Standard Functions 2 70 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 110: ...2 Standard Functions 2 76 NX series Safety Control Unit Instructions Reference Manual Z931 ...
Page 265: ...I 1 I NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 268: ...I 4 NX series Safety Control Unit Instructions Reference Manual Z931 Index ...
Page 269: ......