6-3 PT Settings
6-30
1. Change the contrast setting using the left and right arrow buttons (<<, <, >, >>) for contrast ad-
justment. The contrast will change as soon as the buttons are pressed.
<< Button: Decreases the contrast by ten degrees.
< Button: Decreases the contrast by one degree.
> Button: Increases the contrast by one degree.
>> Button: Increases the contrast by ten degrees.
Check the contrast from the sample display of eight shades above the arrow buttons.
6-3-12 CJK Han Unification Priority
The CJK Han unification setting is used to select what character style (traditional Chinese,
simplified Chinese, or Japanese) will be given priority for display.
If Japanese or Chinese is used, the displayed character form will differ even if the character
code is the same. In this case, use the CJK Han unification priority setting to select what
character style will be given priority for display. Use the following procedure starting from the
PT Settings
Tab in the System Menu to select the priority.
1. In
the
CJK Priority
Area, select from
J
Æ
C (Simplified)
Æ
C (Traditional), C (Simplified)
Æ
C (Traditional)
Æ
J
, or
C (Traditional)
Æ
C (Simplified)
Æ
J
.
“J” indicates Japanese and “C” indicates Chinese.
2. After completing the setting, press the
Write
Button. The setting will be saved.
6-3-13 Alarm Monitor Registration Procedure
Set the method for performing monitor registration of alarms and events.
Normally, the method is set to
When switching screens
.
If multiple alarms or events are registered, the screen-switching speed may increase if the
At
startup
Option is selected. If there is no difference, set the method to
When switching
screens
.
Set the alarm monitor registration method by performing the following operation from the PT
Tab Page in the System Menu.
1.
Set
either
At startup
or
When switching screens
for the alarm monitor registration
method.
2. After completing the setting, press the
Write
Button. The setting will be saved.
6-3-14 Starting the Ladder Monitor from Alarm/Event Summary and His-
tory (NS15/12/10/8 Only)
You can start the Ladder Monitor if an alarm or event is selected in the Alarm/Event Sum-
mary and History.
Summary of Contents for NS15-V2 Series
Page 1: ...Cat No V083 E1 14 Programmable Terminals NS Series SETUP MANUAL...
Page 2: ......
Page 34: ...1 4 Procedure for Running NS series PTs 1 12...
Page 54: ...2 2 Part Names and Functions 2 20...
Page 144: ...4 4 Recommended Connector Cables 4 28...
Page 174: ...5 3 Connecting to Host via EtherNet IP 5 30...
Page 246: ...6 11 Verifying Tags 6 72...
Page 280: ...Appendix 2 Dimensions A 20 NS5 V1 V2 Cable Connection Dimensions...
Page 333: ......
Page 334: ......