What can be done by the setting tool
Setting Change
In the setting console, all beams are set as a floating blanking zone.
With the PC tool for F3SJ, it is possible to set a range of floating blanking zone.
Configure for each CH in case of a series connection.
*1
If this function is enabled, and if either beam of F3SJ's ends is configured as a floating blanking
zone, it is excluded from floating blanking zone.
In figure 11, for example, bottom and top beams setting of blanking zone is ignored and a zone from
the 2nd to 15th beams is set as a floating blanking zone.
*2
Monitoring is disabled for non-sequential beam mode.
*3
To connect the setting console and F3SJ for which followings are configured, you must execute the
setting recovery on connection to recover factory shipment setting.
- Blanking zone is partially set
- Floating blanking monitoring function is being disabled
*4
In case of PC tool for F3SJ, other zone must be specified than outermost beams.
• Detection Capability
Detection capability of F3SJ can differ based on number of floating beams as shown below.
Minimum detection capability and number of beams for which safety output should be turned OFF
Limitation for Combination with Other Functions
You can use muting, fixed blanking, and warning zone functions in combination only with the PC tool
for F3SJ. Note that there is a limitation for setting with zones.
The setting console cannot combine these functions.
For details, see Setting Zone Adjacent Conditions p.91 .
Setting Zone Adjacent Conditions p.91
Function
Initial Setting
Available Setup Item
Setting Console
PC Tool For
F3SJ
Floating Blanking Function
Disable
Enable/disable
*3
Blanking Zone Bottom Beam
0
1 to Number of Beams
– (Fixed to bottom)
Blanking Zone Top Beam
0
1 to Number of Beams
– (Fixed to top)
Both End Beam Disabling Mode *
1
Disable
Enable/disable
*4
Floating Blanking Mode
Sequential
Beam Mode
Sequential Beam Mode/
Non-Sequential Beam Mode
Number of Floating Beams
1
1~4
Number of Allowable Beams
0
0~3
Floating Blanking Monitoring Function *
2
Lockout
Lockout / Monitoring
Disabled
–
Model
Number of Floating Beams and Detection Capability
Not specified
Setting 1
Setting 2
Setting 3
Setting 4
F3SJ-A
N14 series
14 mm
23 mm
32 mm
41 mm
50 mm
F3SJ-A
N20 series
20 mm
35 mm
50 mm
65 mm
80 mm
F3SJ-A
N25 series
25 mm
45 mm
65 mm
85 mm
105 mm
F3SJ-A
N30 series
30 mm
55 mm
80 mm
105 mm
130 mm
F3SJ-A
N55 series
55 mm
105 mm
155 mm
205 mm
255 mm
Number of beams for which safety output is turned OFF 1 beam
2 beams
3 beams
4 beams
5 beams
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...