74
Ch
apt
e
r
3
Set
ting Adjust
ed
to Appl
ication
F3SJ-A
User’s Manual
What can be done by the setting tool
2. Non-Sequential Beam Mode
1. Sequential Beam Mode
If a size of an interrupting object is specified size or smaller, safety output is not turned OFF.
But if interrupting object(s) enter more than one zone of detection zone, safety output is turned OFF.
Under this mode, floating blanking monitoring can be configured. (It cannot be if number of floating
beams is 1)
For minimum detection capability, see “Detection Capability”.
For a size of an object which should not be detected, see “Floating Beam”.
- Floating Blanking Function p.70
- Detection Capability p.76
- Floating Beam p.71
Setting Example: F3SJ-A
N20 series
If number of floating beams is 3, minimum detection capability is 65mm.(Figure 1)
If number of floating beams is 3, and if diameter of an interrupting object is 40mm or smaller, safety
output is not turned OFF. (Figure 2)
If monitoring function is enabled and number of allowable beams is 2, the F3SJ locks out if an
interrupting object is removed or its diameter gets smaller than 20mm. (Figure 3)
Safety output can be turned OFF when more than one zone is interrupted by object(s) that should not
turn the safety output OFF. (Figure 4)
2. Non-Sequential Beam Mode
When total number of interrupted beams in an zone reaches the designated number or more, it is
evaluated as interruption.
Safety output OFF
Not specified
Dia. 65mm
Floating blanking zone
Floating blanking zone
Figure 1
Figure 2
13th beam
13th beam
3rd beam
3rd beam
Safety output does
not turn OFF
Setting number of floating beams to 3
Interrupting object diameter 40mm max.
Dia. 40mm
Lockout
Interrupting object diameter 20mm max.
Interrupting object is removed
More than one zone is interrupted
Figure 3
Figure 4
Safety output OFF
Floating blanking zone
Floating blanking zone
13th beam
3rd beam
13th beam
3rd beam
Dia. 20mm max.
Dia. 30mm
Dia. 30mm
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...