51
F3SJ-A
User’s Manual
Chapter
2
Mu
ting Sys
te
m
System Configuration and Functions
E
Reference: Preventing light interference of muting sensor
When a photoelectric sensor is used as a muting sensor, light interference may cause a muting error of F3SJ.
Light interference may occur due to:
(1) Interference between muting sensors
• Use sensors with mutual interference prevention (such as retro-reflective E3Z-R
series)
• Use laser-type sensors (such as laser-type E3Z-LR
series)
• Take distance from a sensor causing the interference
• Displace beams for each other to prevent interference (change installation height or place them crosswise)
• Install a barrier
• Attach interference prevention filter (provided for E3Z series as accessories)
• Attach a slit to reduce light intensity (provided for E3Z series as accessories)
• Lower the sensitivity
• Reduce a distance between a workpiece and a muting sensor to prevent reflected light from a workpiece
(2) Interference to a muting sensor from F3SJ
• Configure an operating range of F3SJ by the setting tool
• Take distance (D) from a sensor causing the interference
• Displace beams for each other to prevent interference (change installation height or place them crosswise)
• Install a barrier
• Arrange sensors in alternation
• Lower the sensitivity
(3) Interference from a muting sensor to F3SJ
• Use a red LED type sensor (such as retro-reflective E3Z-R
series)
• Use laser-type sensors (such as laser-type E3Z-LR
series)
• Take distance (D) from a sensor causing the interference
• Displace beams for each other to prevent interference (change installation height or place them crosswise)
• Install a barrier
• Arrange sensors in alternation
• Attach a slit to reduce light intensity (provided for E3Z series as accessories)
Mutual interference between a muting sensor and F3SJ in (2) and (3) above can be prevented by
configuring D satisfying a formula shown below:
• If L = 0.2 to 3m
D = 0.26m or larger
• If L = 3m or larger
D = L x tan5° = L x 0.088m or larger
L : Distance between an emitter and a receiver of F3SJ
D : Distance between a muting sensor and F3SJ
F3SJ
B2
A2
A1 B1
A1
B1
A2 B2
A1 B1
A2 B2
F3SJ
F3SJ
D
Workpiece
Workpiece
Workpiece
Reflected light
Direct light
Light from other F3SJ
L
(1)
(1)
(1)
(1)
(3)
(2)
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...