77
F3SJ-A
User’s Manual
Ch
apt
e
r
3
Set
ting Adjust
ed
to Appl
ication
What can be done by the setting tool
E
Warning Zone Function
Overview
Detection zone can be divided into original detection zone and warning zone.
Warning zone output is non-safety output. You must not include it to calculation of safety
distance. Otherwise safety distance may be reduced, resulting in serious injury.
A warning zone CANNOT be used for safety applications. Always install your system so
that a detection zone should be passed before reaching a source of danger.
Warning zone function can be used only when F3SJ is installed horizontally. It CANNOT
be used when F3SJ is installed vertically.
A warning zone must be configured based on a safety distance.
See "Safety Distance: If a person approaches the detection zone of the F3SJ
perpendicularly p.113 " if a detection zone is within vertically installed F3SJ as shown left.
See "Safety Distance: In case of horizontal approach of a human body to F3SJ's
detection zone p.114 " if a detection zone is within horizontally installed F3SJ as shown
right.
Example
•When a person enters, indicator or buzzer should notify warning without stopping a machine.
*C\CTF
Detection Zone
Warning Zone
Warning Zone
Detection
Zone
Hazard
Warning Zone
Detection Zone
Detection Zone
Hazard
Safety distance (S)
Safety
distance (S)
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...