F3SJ-A
User’s Manual
Appendix
N
Non-sequential beam
mode
In this mode, interruption is determined to have occurred when the total number of interrupted beams is
equal to or greater than the number of beams specified in the setting.
Number of Allowable
Beams
Allowable fixed blanking beams.
It represents a beam out of the target of fixed blanking monitoring although it is a fixed blanking zone.
Allowable floating blanking beams.
F3SJ enters lockout if a size gets under setting value for contiguous floating mode with monitoring
function enabled.
Number of floating
beams
This setting causes the F3SJ output to turn OFF if an interrupting object is larger than each setting
value, when the floating blanking function is enabled.
O
Operating range change
function
This function changes the operating range according to the F3SJ installation distance.
Output operation mode
Details that are output from the auxiliary output or external indicator output.
Override
Function that forcibly turns the safety output ON when the muting function is not working.
Override time limit
The continuation time of the override function. The override state is cancelled if it continues for longer
than this time limit.
P
PC tool for F3SJ
Setting tool that connects to a PC and makes settings with setting software (SD Manager). Setting and
monitoring of all functions is possible.
Position detection
muting mode
Mode that enables the muting function with heterogeneous redundant input.
Power-on time
This is the current power-on time since the power-on time was last reset.
Power-on time
information
This information is output from the auxiliary output or external indicator when the power-on time
exceeds the power-on time threshold value. Note that the power-on time information must be assigned
to an output destination.
Power-on time reset
This function can reset the power-on time of the F3SJ to 0. In the case of series connection, the power-
on time can be reset for each F3SJ CH.
Power-on time threshold
value
This can be output from the auxiliary output or the external indicator output when the power-on time
exceeds this value.
Note that the power-on time information must be assigned to an output mode.
Primary sensor
Name of the F3SJ connected nearest the power supply when series-connected.
R
Reset
Releases the interlock state/lockout state.
Response time from ON
to OFF
Time period from when the F3SJ is blocked until the safety output turns from ON to OFF.
Restart interlock
Enters interlock state when the F3SJ is blocked.
Reverse output mode
In this mode, the logic of the auxiliary output and external indicator output is reversed.
S
Safety output (OSSD)
Outputs NPNwhen receiving light. Can be used for safety applications.
Safety output
information
This information is output from the auxiliary output or external indicator when the auxiliary output turns
ON. Note that safety output information must be assigned to an output destination.
SD Manager
Setting software that is used for the PC tool for F3SJ. Setting and monitoring of all functions is possible.
Secondary sensor
Name used for F3SJ other than the primary sensor, when series-connected.
Sequential beam mode
In this mode, output ON continues even when interrupted, if an interrupting object is within the range of
the specified size in one contiguous zone.
Setting console
Convenient tool for changing and monitoring settings. The setting console can be carried to the site.
There are some functions that cannot be used.
Setting recovery
Function to restore the F3SJ's factory settings or the settings made before the most recent change.
Setting tool
This refers to the F39-MC21 setting console and the F39-GWUM PC tool for F3SJ.
Short-circuit detection
This function puts the F3SJ in lockout when there is short-circuit between the output terminals for the
external indicator.
Standard muting mode
This mode is set as the default factory setting and is used when there is enough space to install muting
sensors at both ends of the F3SJ.
Start interlock
Enters interlock after power is turned ON.
Status information
display
This display can read out the I/O data and status of the F3SJ. This function is available only for the PC
tool for F3SJ.
Term
Definition
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...