External Device Monitoring Function
This function detects malfunctions, such as welding, in external relays (or contactors) that control the
hazardous zone of a machine.
This function constantly monitors that a specified voltage is applied to the receiver's external device
monitoring input line, and enters lockout state when an error occurs. The relay's operational delay can
be up to 0.3s(can be changed by the setting tool) without being evaluated as an error.
For example, if the (N.C.) contact is not closed and a specified voltage is not applied to the external
device monitoring line within 0.3s after the safety outputs turn from ON to OFF, it is evaluated as an
error and enters a lockout state.
To utilize this function properly, use safety relays and contactors that have forcibly guided or
mechanically linked contact structure.
Wiring
Perform wiring so that 0 to 1.5V is applied to the external device monitoring line via the external relay's
normally closed (N.C.) contact.
When external device monitoring function is not being used, apply auxiliary output 1 (output operation
mode is safety output information and reverse output mode is being enabled) for which setting is not
changed to the external device monitoring input or disable external device monitoring function by the
setting tool.
- Wiring when external device monitoring function is used p.27
- Wiring when external device monitoring function is not used p.28
Timing Chart
The F3SJ reads out a device monitoring input value 0.5s or later after the power of the F3SJ is turned
ON. If the status of the safety outputs is changed back to the original status within the allowable delay
time, the F3SJ will not enter the lockout state.
T1: Allowable delay time (can be changed by the setting tool. 0.1 to 2.5s)
Setting Change by the Setting Tool
Following functions can be configured by the setting tool.
External Device Monitoring Function p.101
•Disabling external device monitoring function
•Changing allowable delay time (0.1 to 2.5s)
Operation of the F3SJ's Internal Indicators When External Device Monitoring
Function is Performed
When an input is applied to the external device monitoring input, the external device monitoring
indicator turns ON.
ON
OFF
T1=0.3s
T1=0.3s
ON
OFF
Unblocked
/Blocked
Unblocked
Blocked
External device
monitoring input
Safety output
Lockout
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...