83
F3SJ-A
User’s Manual
Ch
apt
e
r
3
Set
ting Adjust
ed
to Appl
ication
What can be done by the setting tool
E
1.
Before a workpiece passes through
All muting sensors are turned OFF and the safety function of the F3SJ is working.
2.
The muting sensor is blocked and the safety function of the F3SJ is disabled
When muting sensors A1 and B1 are turned ON in this order, and the muting function is enabled. In
this state, the safety function of F3SJ is disabled.
3.
Muting sensor A1 is turned OFF
A workpiece finished passing the muting sensor A1 and the sensor starts turning OFF. For standard
muting system, muting is released here. For exit only muting, F3SJ's safety function is disabled for a
exit only muting delay time: T5.
Workpiece
F3SJ
A1 B1
Hazardous zone
A1 : Muting sensor to be connected
to muting input 1
B1 : Muting sensor to be connected
to muting input 2
V
d2
d1
Workpiece
F3SJ
A1 B1
Hazardous zone
A1 : Muting sensor to be connected
to muting input 1
B1 : Muting sensor to be connected
to muting input 2
V
d2
d1
V
Workpiece
F3SJ
A1 B1
Hazardous zone
A1 : Muting sensor to be connected
to muting input 1
B1 : Muting sensor to be connected
to muting input 2
d2
d1
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...