125
F3SJ-A
User’s Manual
Chapter
4
At
tac
h
ing Ext
e
rna
l Indica
to
rs
Wiring/Installation
E
- Attaching/detaching of a cap or a series-connection cable may cause misalignment of rubber grommet in a connector
assembly.
Press the grommet to the bottom of the connector and attach the connector F3SJ again.
Output Operation
The external indicator output 1 (on the receiver side) is configured as "safety output reverse output
(ON when blocked)", while the external indicator output 2 (on the emitter side) is configured as "lockout
output (ON during lockout)".
When the muting function is used, both the emitter and receiver are configured as muting/override
output (Blinking during muting and during override).
Timing chart of basic system
Setting Change by the Setting Tool
Functional setting is available through the setting tool.
External Indicator Output (Non-Safety Output) p.98
•Changing output operation mode
•Reversing output
•Changing indication mode of external indicator
•Enabling diagnosis function of external indicator
Rubber Grommet
Rubber Grommet
Rubber Grommet in Right Position
Misaligned Grommet
Safety output
ON
OFF
ON
OFF
ON
OFF
Unblocked
/Blocked
Unblocked
Blocked
Lockout
External indicator output 1
External indicator output 2
( Receiver )
( Emitter )
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...