What can be done by the setting tool
E
Setting Change
• Auxiliary Output 1
Configure in a bulk in case of a series connection. (to be written into the primary sensor only)
• Auxiliary Output 2
If F3SJ is used for a muting system, auxiliary output 2 cannot be used because it is used as muting input 2.
Muting System Wiring Diagrams p.40
Output Operation Mode (when assigned to auxiliary output and external indicator
output)
Function
Initial Setting
Available Setup Item
Setting Console
PC Tool For F3SJ
Output Operation Mode Safety Output
Information
See Output Operation Mode
Reverse Output Mode
Enabled
Enable/disable
Lighting-Up Pattern
ON
On/Blink[0.5s]/Blink[1.0s]/
Blink[2.0s]
Auxiliary Output
Diagnosis Function
Disabled
Enable/disable
Function
Initial Setting
Available Setup Item
Setting Console
PC Tool For F3SJ
Output Operation Mode Power-On Time
Information
(30,000 hours)
See table below
Reverse Output Mode
Disabled
Enable/disable
Output Operation Mode
Operational Description
(Output turns ON under following condition)
Setting
Console
PC Tool Forpc
tool for F3SJ
Safety Output Information
When safety output is ON
Light Level Diagnosis Information *
1
When F3SJ is under ON state and light intensity is within a
range from 100 to 130% of ON-threshold for 10 seconds or
longer.
Error/Lockout Information
Under error/lockout state
Muting/Override Information
Under either muting or override state
Blanking/Warning Zone Information *
2
When fixed blanking/floating blanking functions and warning
zone function are enabled
Designated Beam Output Information *
3
When designated beam is interrupted
–
Power-On Time Information
When power-on time exceeds power-on time threshold
Warning Zone Information *
4
When a warning zone is interrupted
Test input ON information
When test input is turned ON
Blanking Beam Incidence Information *
5
When fixed blanking or floating blanking beams are incident
Interlock Information
Under interlock state
Muting Error Information
Under muting error state
Excess Load Switch Frequency
Information
When the load switching frequency exceeds its threshold.
Information Trigger Information
Under either interlock, lockout, or muting error
–
Connected Sensor Individual Output
(1CH)
When safety output of 1CH under series connection is ON
(auxiliary
output 1 only)
(auxiliary
output 1 only)
Connected Sensor Individual Output
(2CH)
When safety output of 2CH under series connection is ON
(auxiliary
output 1 only)
(auxiliary
output 1 only)
Connected Sensor Individual Output
(3CH)
When safety output of 3CH under series connection is ON
(auxiliary
output 1 only)
(auxiliary
output 1 only)
Connected Sensor Individual
Output(4CH)
When safety output of 4CH under series connection is ON
(auxiliary
output 1 only)
(auxiliary
output 1 only)
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...