99
F3SJ-A
User’s Manual
Ch
apt
e
r
3
In
dicat
or/Input
& Ou
tpu
t Set
ting
What can be done by the setting tool
E
• External Indicator 2 (Emitter Side)
*1
For a muting system, muting override output is set.
*2
For a muting system, it is configured as disabled.
*3
For a muting system, it is configured as blinking [1.0s].
Output Operation Mode
See Chapter 3 Auxiliary Output (Non-Safety Output) p.94 Output Operation Mode.
Output Operation Mode p.95
Interlock Function
Overview
Start and restart interlock functions can be configured.
Install the interlock reset switch in a location that provides a clear view of the entire haz-
ardous zone and where it cannot be activated from within the hazardous zone.
Example
•To operate a machine after power-on and inspection
•To restart a machine after safety check when F3SJ was blocked and the machine stopped
Functional Description
• Interlock Function
Chapter 2 Interlock Function p.29
• Start Interlock
With this setting, F3SJ enters interlock only when power is turned ON. Applying reset input can release
interlock state when no interrupting object exists in the detection zone. This can be used to operate a
machine after power-on and inspection.
• Restart Interlock
With this setting, F3SJ enters interlock state only when the sensor is interrupted. Applying reset input
can release interlock state when no interrupting object exists in the detection zone. If F3SJ is blocked,
the machine can be restarted after safety is ensured.
• Interlock Reset
For basic system: Open or apply voltage of 0 to 1.5V for 250ms or longer to the reset input line, and set
it open or apply 9 to Vs (nominal 24V).
For muting system: Apply voltage of 9 to Vs (nominal 24V) for 450ms or longer to the reset input line,
and apply 0 to 1.5V again.
Function
Initial Setting
Available Setup Item
Setting Console
PC Tool For
F3SJ
Output Operation Mode
Lockout
Information *1
See Output Operation Mode
Reverse Output Mode
Disabled *2
Enable/disable
Lighting-Up Pattern
ON *3
On/Blink[0.5s]/Blink[1.0s]/Blink[2.0s]
External Indicator Output
Diagnosis Function
Disabled
Enable/disable
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...