27
F3SJ-A
User’s Manual
Chapter
2
Ba
si
c Sys
te
m
System Configuration and Functions
E
Basic System
Basic system indicates the F3SJ with its default factory settings.
The basic system provides basic safety light curtain functions. Most functions can be used without performing
additional configuration.
Wiring Diagrams
Wiring using manual reset mode, external device monitoring function
K1
K2
S1
S2
* 1
* 1
* 2
K1
K2
K3
+24 V D C
0V
* 2
K4
Interlock selection input (White)
S1
S2
K1, K2
K3, K4
: External test switch (connect to 24V if a switch is not required)
: Interlock/lockout reset switch
: Relay or other device that controls hazardous parts of the machine
: Load or PLC, etc. (for monitoring)
Emitter
Receiver
(Grey) Communication line (+)
(Pink)
Communication line (-)
0V(Blue)
0V(Blue)
Power
supply
Shield
Shield
Reset input(Yellow)
24V(Brown)
24V(Brown)
External device monitoring input
(Red)
Auxiliary output 1(Yellow)
Safety output 2(White)
Auxiliary output 2(Red)
Test input(Black)
Safety output 1(Black)
*3
*3
*1 Use a switch for micro loads (Input specifications: 5V, 1mA)
*2 F3SJ can operate even if K3 and K4 are not connected
*3 Green for the single-ended cable F39-JC
A
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...