Overview and Specifications
E
Display Patterns of the Incident Light Level Indicator
Operation is possible with incident light level of 100% or more, but to ensure stability, operate when all incident light
level indicators
incident light level indicator
Safety Output
ON
ON
ON
OFF
OFF
OFF
Incident light level
170% or
higher
Less than
170%
~
130%
Less than
130%
~
100%
Less than
100%
~
75%
Less than
75%
~
50%
Less than
50%
ON