43
F3SJ-A
User’s Manual
Chapter
2
Mu
ting Sys
te
m
System Configuration and Functions
E
2.
The muting sensor outputs are turned ON (muting inputs are LOW) and the safety function of the F3SJ
is disabled.
When muting sensors A1 and B1 are turned ON in this order, the muting function is enabled. In this
state, the safety function of the F3SJ is disabled.
3.
The muting sensor outputs are turned ON (muting inputs are LOW) and the safety function of the F3SJ
is disabled.
The F3SJ is blocked but the safety function is disabled by the muting function, and safety outputs 1
and 2 are turned ON.
F3SJ
F3SJ
B1
A1
Workpiece
Hazardous zone
Reflector
Reflector
F3SJ
F3SJ
B1
A1
Workpiece
Reflector
Reflector
Hazardous zone
Summary of Contents for F3SJ Series
Page 1: ...F3SJ A N Series Version 2 Safety Light Curtain User s Manual Cat No SCHG 719K...
Page 19: ...xvii F3SJ A User s Manual Introduction Contents E Revision History 202...
Page 20: ...xviii Introduction Contents F3SJ A User s Manual...
Page 184: ...164 Chapter 4 Wiring F3SJ A User s Manual Wiring Installation...
Page 192: ...172 Chapter 5 Wiring Examples F3SJ A User s Manual Input Output Circuit and Applications...