76
Chapter
4
Wiring
F3SG-4RA-25-02TS
User’s Manual
Wiring/Installation
If the length of the Cascading Cable is insufficient, connect the F39-JD
B Double-Ended Cable
between the power cable of the F3SG-R and the F39-JGR2WTS Cascading Cable, as required.
(Cable length between sensors: 10 m max. (not including cascading cable (F39-JGR2WTS) and power
cable))
4-5-3-5. Reduced Wiring Connector System
Reduced Wiring Connector System
The reduced wiring system can be achieved by using the Double-Ended Cable for Emitter (F39-JD
□
-
B-L), the Single-Ended Cable for Receiver (F39-JD
□
A-D) and the Reduced Wiring Connector (F39-
CN5).
When using the Reduced Wiring Connector (F39-CN5), the following functions are not available.
- External Device Monitoring
- Auxiliary Output
Cable for Reduced Wiring (F39-JD
□
BA, sold separately)
A set of two cables; a Double-Ended Cable for Emitter (F39-JD
□
B) and a Single-Ended Cable for
Receiver (F39-JD
□
A-D). Used in combination with a reduced wiring connector (F39-CN5, sold
separately).
See the following pages for details of the Double-Ended Cable for Emitter (F39-JD
□
B) and the Single-
Ended Cable for Receiver (F39-JD
□
A-D).
F3SG-R Emitter
F3SG-R Receiver
Cable is gray
Model F39-JD
B-L(Gray)
Double-Ended Cable
Model F39-JD
B
Cable is black
Model F39-JD
B-D(Black)
Cascading Cable
Model F39-JGR2WTS
F3SG-R Emitter
F3SG-R Receiver
Cable is gray
Cable is black
Remove the cap
Remove the cap
F39-CN5
Reduced Wiring Connector
F39-JD
□
B-L
Double-Ended Cable (Gray)
F39-JD
□
A-D
Single-Ended Cable (Black)
F3SG-R
Emitter
F3SG-R
Receiver
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...