52
Chapter
4
Dimens
io
ns
F3SG-4RA-25-02TS
User’s Manual
Wiring/Installation
4-3-3-2. Side Mounting
4-4-3-2. Mounting with Top/Bottom Bracket (F39-LGRTB-
) and Intermediate Bracket (F39-LGRA)
- Use the brackets of specified quantities and locations according to the dimensions. The other brackets than described
above may not meet the specified ratings and performance.
- When you use the sensor in a situation where the sensor is under a load, increase the number of the brackets used.
- This bracket allows beam alignment after fixing the bracket to a wall surface.
- The angle adjustment range is ±22.5° when using the Top/Bottom Brackets only. The angle adjustment range is ±15°
when using the Top/Bottom Brackets and Intermediate Bracket together.
31.4
10
10
P
D
N1
N2
56.5
C
F
F
20
20
H
56.5
C
F
I
G
3
4.15
4.15
2-M4
4-M5
2-M8
2-M6
16.3
73
6.3
I
J
24.5
23.5
32
50
38
5.5
6.5
4.15
56.5
G
H
20
19.35
F39-LGRTB-2
(F39-LGRA)
(F39-LGRTB-2)
Φ9
46.35
2-M4
<Screw for Top/Bottom
Bracket: M5>
<Screw for Top/Bottom
Bracket: M6 or M8>
Intermediate Bracket
Top/Bottom Bracket
Top/Bottom Bracket
Backside:2-M4
C(Protective height)
2-M5 or M6
2-M5 or M6
[ Unit : mm ]
*The number of brackets required to mount either one of emitter and receiver.
Dimension
C
4-digit number of the type name (Protective height)
Dimension
D
C-20
Dimension
G
C+51+N1+N2
Dimension
H
C+54+N1+N2
Dimension
I
C+88+N1+N2
Dimension
J
C+106+N1+N2
Dimension
N1
0 to 30
Dimension
N2
0 to 13
Dimension
P
20
Protective height (C)
Number of Top/Bottom Brackets *
Number of Intermediate Brackets *
Dimension
F
0240 to 1040
2
0
-
1120 to 1920
2
1
1000 mm
max.
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...