9
F3SG-4RA-25-02TS
User’s Manual
Chapter
1
Ra
tings
/Sp
ecif
ic
a
tion
s
Overview and Specifications
E
Functional
Mutual Interference Prevention
(Scan Code)
This function prevents mutual interference in up to two F3SG-R systems.
4-1-4. Mutual Interference Prevention
Cascade Connection
Number of cascaded segments: 3 max.
(only among F3SG-4RA
□□□□
-25-02TS's)
Total number of beams: 255 max.
Cable length between sensors: 10 m max. (not including cascading cable (F39-JGR2WTS) and power
cable)
Test Function
Self-test (at power-on, and during operation)
External test (light emission stop function by test input)
Safety-Related Functions
External device monitoring (EDM)
Scan code selection
Environmental
Ambient
Temperature
Operating
-10 to 55°C (14 to 131°F) (non-icing)
Storage
-25 to 70°C (-13 to 158°F)
Ambient
Humidity
Operating
35% to 85% (non-condensing)
Storage
35% to 95%
Ambient Illuminance
Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
Degree of Protection
(IEC 60529)
IEC 60529: IP65 and IP67, JIS C 0920 Annex 1: IP67G
Vibration Resistance
(IEC 61496-1)
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
Shock Resistance
(IEC 61496-1)
100 m/s
2
, 1000 shocks for all 3 axes
Pollution Degree
(IEC 60664-1)
Pollution Degree 3
Connections
Power cable
Type of
Connection
M12 connectors: 8-pin emitter and receiver. Cables prewired to the sensors.
IP67 and IP67G (JIS C 0920 Annex 1)* rated when mated.
*F3SG-R meets the degree of protection when it is correctly connected with an F39-JD
□□
RA-
□
Oil-
resistant cable.
Number of
Wires
Emitter: 5, Receiver: 8
Cable
Length
0.3 m
Cable
Diameter
6 mm
Minimum
Bending
Radius
R36 mm
Cascading cable
Type of
Connection M12 connectors: 8-pin emitter and receiver. IP67 rated when mated.
Number of
Wires
Emitter: 5, Receiver: 8
Cable
Length
0.3 m
Cable
Diameter
6 mm
Minimum
Bending
Radius
R5 mm
F3SG-4RA
-25-02TS
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...