84
Ch
apt
e
r
5
Wir
ing Examples
F3SG-4RA-25-02TS
User’s Manual
Input/Output Circuit and Applications
5-2-3. F3SG-R with Reduced Wiring Connector
The following is the example of External Test in 24 V Active (not used).
[Settings]
The reduced wiring system can be achieved by using the Reduced Wiring Cables (F39-JD
□
BA) and
the Reduced Wiring Connector (F39-CN5).
[Wiring Example]
When using the Reduced Wiring Connector (F39-CN5), the following functions are not available.
- External Device Monitoring
- Auxiliary Output
The wiring example does not indicate functional earth. To use functional earth, wire an earth cable according to the
example in
5-2-1. EDM used and External Test in 24V Active not used
. Also refer to
4-5-4. Functional Earth Connection
for more information.
Function
Emitter
External Test: 24 V Active (End Cap: Black) (factory default setting)
F39-JD
□
B-L
F39-CN5
F39-JD
□
A-D
KM1
KM2
M
+24 VDC
0 VDC
Power Supply
+24 VDC (Brown)
TEST (Red) *
OSSD 1 (Black)
OSSD 2 (White)
Not Used (Yellow)
PC COM(+) (Gray)
PC COM(-) (Pink)
0 VDC (Blue)
Shield
KM1 KM2
KM1, KM2: Safety relay with forcibly guided contacts (G7SA)
M: Motor
Emitter
Receiver
Unblocked
Blocked
Beam state
OSSD
*Connect the line to 24 V via a test switch (N.O. contact) if
External Test is used.
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...