16
Chapter
2
Scan C
ode Selection
F3SG-4RA-25-02TS
User’s Manual
System Operation and Functions
2-3. Scan Code Selection
2-3-1. Overview
The F3SG-R has two scan codes (Code A and Code B). These scan codes have different internal
processing time. The use of different scan codes allows for placement of systems in close proximity
and in line with each other and minimize mutual interference.
The response time for Code A is 1 ms shorter than that for Code B.
1-6-1. List of Models/Response Time/Current Consumption/Weight
for more information on the response
time.
Refer to
4-1-4. Mutual Interference Prevention
for how to mitigate mutual interference.
2-3-2. Factory Default Setting
The factory default setting is Code A.
Both the emitter and receiver units must be set to the same code.
2-3-3. Setting
The user can select the scan code from Code A or Code B by the Rotary Switch.
Refer to
Chapter 3 Setting with Rotary Switch and End Cap
for more information on setting this function by
the Rotary Switch or End Cap Switch.
Rotary Switch