20
Chapter
2
Lo
cko
ut Res
et
F3SG-4RA-25-02TS
User’s Manual
System Operation and Functions
2-6. Lockout Reset
2-6-1. Overview
When the cause of the Lockout is removed, you can release the Lockout state of the F3SG-R by using
either of the following methods.
• Cycle the power back ON
• Lockout reset input
Open or apply 0 V to 1/2 Vs to the EDM line (red) for 1 s or longer, and then apply a voltage of Vs-3 V
to Vs again.
Basic wiring diagram
Timing chart
The table below shows the relation between the ON/OFF states and external lines.
Input
External Connection
ON
Vs-3 V to Vs
OFF
0 V to 1/2 Vs, or open
S1: Lockout reset switch
KM1, KM2: External device
*Also used as lockout reset line
KM1
F39-JD
A-D
KM2
Receiver
Power supply
0 VDC : Blue
EDM : Red *
+24 VDC : Brown
0 VDC
+24 VDC
S1
Lockout reset
OFF
ON
Lockout reset
1 s or more
1 s or more