41
F3SG-4RA-25-02TS
User’s Manual
Chapter
4
Instal
lati
on C
o
nsider
a
tion
s
Wiring/Installation
E
4-1-4. Mutual Interference Prevention
Do not use the sensor system with mirrors in a retro-reflective configuration. Doing so
may hinder detection. It is possible to use mirrors to alter the detection zone to a 90-
degree angle.
When using more than 1 set of F3SG-R in adjacent areas, the emitter of one F3SG-R
may interfere with the receiver of the other, causing the safety functions to stop working
properly. Install and configure them so that mutual interference does not occur.
When two or more F3SG-R systems are mounted in close proximity to each other, precautions should
be taken to avoid one system interfering with another, such as by back-to-back configuration, physical
barrier, Scan Code Selection and adjustment of distance between adjacent sensors.
Example
The scan code feature of the F3SG-R system allows for placement of systems in close proximity and in
line with each other. The distinctive coding of the beams provide for unique operation of a system while
in view of another system with a different scan code. Two unique codes are available on the F3SG-R.
The emitter and receiver units must be set to the same scan code for the receiver to enter the Machine
Run state. The scan code is selectable by the Rotary Switch on the emitter and receiver units.
Refer to
for more information on the scan code feature.
Refer to
for more information on setting the scan code by the Rotary Switch.
Emitter
Receiver
Machine 1
Emitter
Receiver
Machine 2
PREFERRED INSTALLATION 1
Code A
Code A
Emitter
Receiver
Machine 2
Machine 1
Emitter
Receiver
PREFERRED INSTALLATION 2
Code A
Code A
Emitter
Receiver
Machine 2
Machine 1
Emitter
Receiver
NOT RECOMMENDED INSTALLATION
Code A
Code A
Back-to-back configuration
Physical barrier between systems
PREFERRED INSTALLATION 3
Emitter
Receiver
Emitter
Receiver
Code A
Code A
Code A
Code A
L
D
5°
5°
Distance between emitter and
receiver (operating range L)
Allowable installation distance
D
For 0.2 to 3m
0.26m
For 3m or more
L x tan5 ° = L x 0.088 (m)
Machine 1
Emitter
Emitter
Receiver
Machine 2
Receiver
Code A
Code B
Scan code setting when two or more systems are mounted
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...