2-8. Auxiliary Output
Do not use the auxiliary output for safety applications.
Failure to do so may result in serious injury when the F3SG-R fails.
2-8-1. Overview
The auxiliary output is used to monitor the status of F3SG-R. This output can be connected to a device
such as an indication lamp, programmable controller, etc.
Basic wiring diagram
The load current of the auxiliary output is 100 mA max.
2-8-2. Factory Default Setting
The factory default setting is inverted signal of the safety output.
Load
AUX: Yellow
0 VDC: Blue
F3SG-R
Receiver
+24 VDC: Brown
+24 V
0 V
Toff
Ton
Beam state
Unblocked
Blocked
OSSD
ON
OFF
Auxiliary output
Ton: Response time OFF to ON
Toff: Response time ON to OFF
ON
OFF