6-1. Pre-Operation Checklists
Make sure Responsible Person tests the operation of the F3SG-R after installation to verify that
the F3SG-R operates as intended. Make sure to stop the machine until the test is complete.
Unintended function settings may cause a person to go undetected, resulting in serious injury.
After installation, the highest level administrator must use the following checklist to verify the operation,
placing a check mark in each of the boxes.
6-1-1. Checklists
6-1-1-1. Installation Condition Check
The machine itself does not prevent the operation of safety functions such as stopping.
The hazardous part of a machine cannot be reached without passing through the detection zone of
the F3SG-R.
The system is configured so that the F3SG-R can always detect a worker who is working in the
hazardous zone.
The reset switch is installed in a location that provides a clear view of the entire hazardous zone and
it cannot be activated from within the hazardous zone.
Safety distance has been calculated. Calculated distance: S = ( )mm
The actual distance is equal to or greater than the calculated distance. Actual distance = ( )mm
Reflective surfaces are not installed in prohibited zones.
Not installed in a retro-reflective configuration.
It is not used in flammable or explosive atmosphere.
6-1-1-2. Wiring Check Before Power Is Turned ON
When the power supply unit is connected to multiple devices, the power supply unit must have
tolerance against total rated current of the devices.
The power supply unit is a 24 VDC unit that conforms to the EMC Directive, Low-voltage Directive,
and output holding time specifications.
The power supply polarity is not connected in reverse.
Emitter/receiver cables are properly connected to the respective emitters/receivers.
Double insulation is used between I/O lines and the hazard potential (commercial power supplies,
etc.).
The outputs are not short-circuited to +24 VDC line.
No loads are connected to +24 VDC line.
All lines are not connected to commercial power source.
F3SG-R's power supply connector and series connection connector must not be attached upside
down.
Model of emitter and receiver must be the same.
When 2 or more F3SG-R systems are used, they are in cascade connection or prevented from mutual
interference with each other.
On a secondary sensor farthest from its power supply, either of the following is attached:
- End Cap
- Lamp (F39-LP and F39-BTLP, sold separately)
- Bluetooth
®
Communication Unit (F39-BT, sold separately)
Neither connector, cap, or bracket must be loose.
Auxiliary output must not be used as safety output.
+24 VDC line of the power supply must not be grounded.
Wiring must not be bent, cracked, nor damaged.
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...