96
Chapter
7
Tro
ubles
hoot
in
g
F3SG-4RA-25-02TS
User’s Manual
Appendix
Description
Error code
Cause and measures
Cap error
4F
A cap may be detached. Attach the cap properly.
Other sensor error
38
Other sensor being cascaded caused an error. Check the indicator of the
sensor.
Cascading configuration error
39, 3A, 3B
The cascading cable may be short-circuited, broken, or disconnected. Check
that the cascading cable should be tightly connected. If the cascading cable is
broken, replace it.
The number of connected sensors or beams may have exceeded the
maximum value due to cascading.
Check the configuration.
External device monitoring error
52
Relay may be welded.
Replace the relay.
The relay and the EDM line may not be properly wired.
Check the wiring with the relay.
The relay response time may be exceeding the allowable delay time.
Change the allowable delay time or replace the relay with one that has an
appropriate response time.
2-7. External Device Monitoring (EDM)
Safety output error
60, 6B, 6C
Safety output lines may be short-circuited to each other or another signal line
may be short-circuited to the safety output line.
Wire the safety output lines properly.
Communication error
30, 31, 32
The communication line or other wiring may be broken or short-circuited.
Check the cables for cascading or extension cables.
If the wiring is extended with cables other than specified, the cables used for
extension may not have performance equivalent or greater than the specified
cables. Use cables with the same performance or more than the specified
cables.
Scan code setting error
E7, E8
A scan code setting may have been changed during operation.
Check if there is any change to the scan code setting.
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...