User’s Manual
Wiring/Installation
4-4. Mounting
4-4-1. Mounting Method
You can mount the F3SG-R with Free-Location Brackets and Top/Bottom Brackets. Any of these
mounting methods allows the user to use the same bracket for the backside mounting and side
mounting.
4-4-2. Number of Brackets Required
The numbers of brackets required according to the protective heights of the sensor are as follows:
• Mounting with Free-Location Brackets Only
• Mounting with Top/Bottom Brackets (F39-LGRTB-
□
) and Intermediate Bracket (F39-LGRA)
*1. The number of brackets required to mount either one of emitter and receiver.
*2. Mounting an emitter or receiver with one bracket is possible for the model of protective height of 0240. In this case, locate this
bracket at the center of the sensor length.
Make sure that the F3SG-R is securely mounted and its cables and connectors are properly connected.
Protective height
Number of Free-Location Brackets *1
0240 to 1200
2 *2
1280 to 1920
3
Protective height
Number of Top/Bottom Brackets *1
Number of Intermediate Brackets *1
0240 to 1040
2
0
1120 to 1920
2
1
[ Unit : mm ]