31
F3SG-4RA-25-02TS
User’s Manual
Ch
apt
e
r
3
End Ca
p
Setting with Rotary Switch and End Cap
E
3-4. End Cap
Make sure to test the operation of the F3SG-R after setting with End Cap to verify that the F3SG-
R operates as intended. Make sure to stop the machine until the test is complete. Unintended
settings may cause a person to go undetected, resulting in serious injury or death.
Connect the load between the output and 0 V line. Connecting the load between the output and a
different power supply line from the above will result in a dangerous condition because the
operation mode of safety output is reversed to "Dark-ON".
Do not 24 VDC line. Otherwise, a ground fault may turn the safety output ON, resulting
in a failure of stopping the machine.
F3SG-R series has End Cap to configure the function at the opposite end from the power cable of the emitter.
Configure the function before installing the F3SG-R in your site. Make sure to turn the power off the F3SG-R
before replacing the End Cap.
For F3SG-R series, the following functional setting is available by replacing the End Cap on the emitter.
- The End Cap is not intended to be used for the receiver. Do not connect the End Cap to the receiver.
- Do not remove the insulating rubber attached to the End Cap. Failure to do so may cause deterioration of the protective
functions.
- When attaching the End Cap, tightly fasten the screw (M2.5, recommended torque: 0.35N•m). Failure to do so may cause the
End Cap to come loose, leading to deterioration of the protective functions.
- The insulating rubber attached to connector of the End Cap may come off when removing the End Cap. If the rubber comes off,
place it back to the groove of the connector and insert the connector to the sensor body.
Function
End Cap
Description
Refer to
External Test Input
Selection
24 V Active (factory default setting)
0 V Active
Black
White
Summary of Contents for F3SG-R Series
Page 19: ...xvii F3SG 4RA 25 02TS User s Manual Introduction E 7 4 Revision History 107...
Page 20: ...xviii Introduction F3SG 4RA 25 02TS User s Manual...
Page 52: ...32 Chapter 3 End Cap F3SG 4RA 25 02TS User s Manual Setting with Rotary Switch and End Cap...
Page 112: ...92 Chapter 6 Maintenance Checklists F3SG 4RA 25 02TS User s Manual Checklists...