62
Editing Parameters
Section 3-1
3-1-4
Safety Input Parameter Groups
This section describes parameters in the safety input parameter groups.
The safety input parameters are grouped by terminal number.
Item
Settings
Description
Default
S
Off On Delay
0 to 126 ms
(in 6-ms increments)
Sets the OFF/ON delay time.
0 ms
S
On Off Delay
0 to 126 ms
(in 6-ms increments)
Sets the ON/OFF delay time.
0 ms
S
Safety Input Channel
Mode
Not Used.
The safety input is not used. (External input
device not connected.)
Not Used.
Test pulse from test out
Specifies connecting a device with a contact
output in combination with a test output.
When this mode is selected, select the test
output to use for the test source and then set
the test output mode to
Pulse Test Output
.
When these settings are made, contact
between the input signal line and the power
supply (plus) and short circuits with other input
signal lines can be detected.
Used as a safety input.
Specifies connecting a safety device with a
semiconductor output, such as a light curtain.
Used as a standard
input.
Specifies connecting a standard device (i.e., a
non-safety device).
S
Test Source
Not Used.
If the channel mode of a safety input is set to
Test Pulse from Test Out
, the test output is
selected for use in combination with the safety
input. Set the channel mode of the test output
selected here to
Pulse Test Output
.
Not Used.
Test Output 0
Test Output 1
Test Output 2
Test Output 3
S
Dual Channel Safety
Input Mode
Single Channel
Specifies using Single Channel Mode.
If
Single Channel
is selected, the safety input
that would be paired for the dual channel
parameter will also be set to Single Channel
Mode.
Dual Chan-
nel Equiva-
lent
Dual Channel Equiva-
lent
Specifies using the Dual Channel Equivalent
Mode with a paired safety input.
Dual Channel Comple-
mentary
Specifies using Dual Channel Complemen-
tary Mode with a paired safety input.
Summary of Contents for DST1-ID12SL-1
Page 1: ...OPERATION MANUAL Cat No Z904 E1 06 DeviceNet Safety DST1 series Safety I O Terminals...
Page 2: ......
Page 3: ...DST1 series Safety I O Terminals Operation Manual Revised June 2011...
Page 4: ...iv...
Page 10: ...x...
Page 14: ...xiv...
Page 110: ...86 Remote I O Allocations Section 3 2...
Page 116: ...92 Indicators Section 4 2...
Page 134: ...110 DST1 XD0808SL 1 Section 5 4...
Page 146: ...122 Maintenance Section 7 4...
Page 159: ...135 Logic Terminal Wiring Examples Section 8 3...
Page 160: ...136 Logic Terminal Wiring Examples Section 8 3...
Page 178: ...154 Index...
Page 181: ...157 Revision History...