34
Maintenance Functions of DST1-series Safety I/O Terminals
Section 1-7
1-7-4
Monitoring the Contact Operation Counters
Description
A DST1-series Safety I/O Terminal totals the number of times each safety
input contact, test output contact, and safety output contact turns ON and
internally saves the data in non-volatile memory. If the value of a counter
reaches the threshold value, the Connected Component Maintenance Flag in
General Status will turn ON.
• Measurement count:
0 to 4,294,967,295 counts
(stored data: 0000 0000 to FFFF FFFF hex)
• Measurement unit:
Operations
• Maximum resolution:
166.7 Hz
The user can monitor this information using the Network Configurator and
explicit messages.
Note
• One contact cannot be used at the same time for both the time and
count monitoring functions. Select only one of these in the
Mainte-
nance Counter Mode Choice
.
• If the
Maintenance Counter Mode Choice
is changed, the counter or
time data saved internally will be cleared.
• This function does not operate when the I/O power supply is OFF.
Safety I/O Terminal
Record in the Slave
Number of times output
contact changes to ON.
Output device
(e.g., relay)
I/O power
Number of
operations
Summary of Contents for DST1-ID12SL-1
Page 1: ...OPERATION MANUAL Cat No Z904 E1 06 DeviceNet Safety DST1 series Safety I O Terminals...
Page 2: ......
Page 3: ...DST1 series Safety I O Terminals Operation Manual Revised June 2011...
Page 4: ...iv...
Page 10: ...x...
Page 14: ...xiv...
Page 110: ...86 Remote I O Allocations Section 3 2...
Page 116: ...92 Indicators Section 4 2...
Page 134: ...110 DST1 XD0808SL 1 Section 5 4...
Page 146: ...122 Maintenance Section 7 4...
Page 159: ...135 Logic Terminal Wiring Examples Section 8 3...
Page 160: ...136 Logic Terminal Wiring Examples Section 8 3...
Page 178: ...154 Index...
Page 181: ...157 Revision History...