18
Logic Functions
Section 1-5
1-5-3
Parameters That Can Be Set
Data That Can Be Set for Input Condition Signals
The following data is used for remote I/O data. For details on remote I/O allo-
cations, refer to
.
Example 1: IN0 and IN1 Used in Single Channel Mode
IN0 input condition signal:
Bit 0 input condition signal 0 (0/1)
is used.
IN1 input condition signal:
Bit 1 input condition signal 1 is used.
Example 2: IN0 and IN1 Used in Dual Channel Mode
IN0 input condition signal:
Bit 0 input condition signal 0 (0/1)
is used.
IN1 input condition signal:
Not Used.
Data That Can Be Set for Reset Signals
The following data is used for remote I/O data. For details on remote I/O allo-
cation, refer to
.
Example 1: IN0 and IN1 Used in Single Channel Mode
IN0 reset signal: Bit 0 reset signal 0 (0/1) is used.
IN1 reset signal: Bit 1 reset signal 1 is used.
Example 2: IN0 and IN1 Used in Dual Channel Mode
IN0 reset signal: Bit 0 reset signal 0 (0/1) is used.
IN1 reset signal: Setting not required.
Name
Option
Setting range
Input condi-
tion signal
Remote I/O
Remote safety I/O data (received from Safety Master through the
network)
Input 0 to Input 5
Safety input terminals IN0 to IN5
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved for
system.
Input
condition
signal
No. 5
Input
condition
signal
No. 4 (4/5)
Input
condition
signal
No. 3
Input
condition
signal
No. 2 (2/3)
Input
condition
signal
No. 1
Input
condition
signal
No. 0 (0/1)
Name
Option
Setting range
Reset signal
Remote I/O
Low-High-
Low
Remote safety I/O data (received from Safety Master or Standard
Master through the network) used for a Low-high-Low reset.
Remote I/O
Rising Edge
Remote safety I/O data (received from Safety Master or Standard
Master through the network) used for a Rising Edge reset.
IN6 Low-
High-Low
The IN6 terminal is used for a Low-High-Low reset.
IN6 Rising
Edge
The IN6 terminal is used for a Rising Edge reset.
IN7 Low-
High-Low
The IN7 terminal is used for a Low-High-Low reset.
IN7 Rising
Edge
The IN7 terminal is used for a Rising Edge reset.
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Reserved for system. Reset sig-
nal
No.5
Reset sig-
nal
No.4 (4/5)
Reset sig-
nal
No.3
Reset sig-
nal
No.2 (2/3)
Reset sig-
nal
No.1
Reset sig-
nal
No.0 (0/1)
Summary of Contents for DST1-ID12SL-1
Page 1: ...OPERATION MANUAL Cat No Z904 E1 06 DeviceNet Safety DST1 series Safety I O Terminals...
Page 2: ......
Page 3: ...DST1 series Safety I O Terminals Operation Manual Revised June 2011...
Page 4: ...iv...
Page 10: ...x...
Page 14: ...xiv...
Page 110: ...86 Remote I O Allocations Section 3 2...
Page 116: ...92 Indicators Section 4 2...
Page 134: ...110 DST1 XD0808SL 1 Section 5 4...
Page 146: ...122 Maintenance Section 7 4...
Page 159: ...135 Logic Terminal Wiring Examples Section 8 3...
Page 160: ...136 Logic Terminal Wiring Examples Section 8 3...
Page 178: ...154 Index...