146
DeviceNet Explicit Messages
Appendix 1
Setting and Monitoring Operation Time
Explicit
message
Read
/write
Function
Command
Response
Data size
Service
Code
Class
ID
Instance
ID
Attribute
ID
Data size
Set Value for
Operation Time
Monitor
Read
Reads the monitor
value for the time
(unit: ms) from when
the output (1 to 8)
specified by the
instance ID turns
ON until the corre-
sponding input turns
ON.
0E hex
97 hex 01 to 08
hex
67 hex
-
2 bytes
0000 to FFFF hex
(0 to 65535)
Write
Writes the monitor
value for the time
(unit: ms) from when
the output (1 to 8)
specified by the
instance ID turns
ON until the corre-
sponding input turns
ON.
10 hex
97 hex 01 to 08
hex
67 hex
2 bytes
0000 to
FFFF hex
(0 to 65535)
Present Value
for Operation
Time Monitor
Read
Reads the present
value for the time
(unit: ms) from when
the output (1 to 8)
specified by the
instance ID turns
ON until the corre-
sponding input turns
ON.
0E hex
97 hex 01 to 08
hex
65 hex
-
2 bytes
0000 to FFFF hex
(0 to 65535)
Monitor Status
Value for Oper-
ation Time
Monitor Read
Read
Reads the monitor
status for the time
(unit: ms) from when
the output (1 to 8)
specified by the
instance ID turns
ON until the corre-
sponding input turns
ON.
0E hex
97 hex 01 to 08
hex
66 hex
-
1 byte
00 hex: Within
range
01 hex: Over
range (over the
monitor value)
Summary of Contents for DST1-ID12SL-1
Page 1: ...OPERATION MANUAL Cat No Z904 E1 06 DeviceNet Safety DST1 series Safety I O Terminals...
Page 2: ......
Page 3: ...DST1 series Safety I O Terminals Operation Manual Revised June 2011...
Page 4: ...iv...
Page 10: ...x...
Page 14: ...xiv...
Page 110: ...86 Remote I O Allocations Section 3 2...
Page 116: ...92 Indicators Section 4 2...
Page 134: ...110 DST1 XD0808SL 1 Section 5 4...
Page 146: ...122 Maintenance Section 7 4...
Page 159: ...135 Logic Terminal Wiring Examples Section 8 3...
Page 160: ...136 Logic Terminal Wiring Examples Section 8 3...
Page 178: ...154 Index...
Page 181: ...157 Revision History...