148
DeviceNet Explicit Messages
Appendix 1
A-1-3
Using Explicit Messages
The following example shows how to use explicit messages with the DST1-series Safety I/O Terminals using a
CS1W-DRM21 DeviceNet Unit (Master).
Example: Reading the Monitor Status for the Operation Time Monitor
Example Conditions
DeviceNet Unit node address: 05
Unit number: 0
Unit address: FE hex (or 10 hex)
DST1 node address: 11
CMND
S
D
C
Input 2
Input 1
Ladder program
Sends explicit message
DST1
DeviceNet Unit
DeviceNet Network
Discrepancy Error
Input 1
Input 2
ON
OFF
ON
OFF
Normal
Input Flag
ON
OFF
Discrepancy time
Error
Summary of Contents for DST1-ID12SL-1
Page 1: ...OPERATION MANUAL Cat No Z904 E1 06 DeviceNet Safety DST1 series Safety I O Terminals...
Page 2: ......
Page 3: ...DST1 series Safety I O Terminals Operation Manual Revised June 2011...
Page 4: ...iv...
Page 10: ...x...
Page 14: ...xiv...
Page 110: ...86 Remote I O Allocations Section 3 2...
Page 116: ...92 Indicators Section 4 2...
Page 134: ...110 DST1 XD0808SL 1 Section 5 4...
Page 146: ...122 Maintenance Section 7 4...
Page 159: ...135 Logic Terminal Wiring Examples Section 8 3...
Page 160: ...136 Logic Terminal Wiring Examples Section 8 3...
Page 178: ...154 Index...
Page 181: ...157 Revision History...