background image

 
 
 

 

 

 

 

 

 

 

FAST

®

 Owner’s Manual 

 

 

 

For use with:

 

 

MicroFAST

®

 0.5, 0.625, 0.75, 0.9, 1.5, 3.0, 4.5 & 9.0 

HighStrengthFAST

®

 1.0, 1.5, 3.0, 4.5, 9.0 

NitriFAST

®

 0.5, 0.625, 0.75, 0.9, 1.5, 3.0, 4.5, 9.0  

RetroFAST

® 

0.15, 0.25, 0.375 

 
 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

Owner’s Manual 

FASTOM-001 REV. 8 AUG 2022 

Summary of Contents for FAST

Page 1: ...Manual For use with MicroFAST 0 5 0 625 0 75 0 9 1 5 3 0 4 5 9 0 HighStrengthFAST 1 0 1 5 3 0 4 5 9 0 NitriFAST 0 5 0 625 0 75 0 9 1 5 3 0 4 5 9 0 RetroFAST 0 15 0 25 0 375 Owner s Manual FASTOM 001 R...

Page 2: ...2...

Page 3: ...S 6 INTRODUCING SUBSTANCES INTO THE SYSTEM 6 SEPTIC DOS AND DON TS 7 Don t Do These Things 7 Do These Things 7 MAINTENANCE AND SERVICE 9 TANK PUMPING PROCEDURE 9 SEASONAL OR INTERMITTENT USE 10 ALARMS...

Page 4: ...e a clean environment for future generations Please take time to read this FAST Owner s Manual where you will find important safety precautions and information on proper use and care of your system De...

Page 5: ...al The FAST assembly consists of two components the treatment module and blower The blower provides air to the system via the air supply pipe The air supply pipe and draft tube create an airlift which...

Page 6: ...iciency of the system or stop the treatment process by destroying the biomass These substances can be grouped as prohibited substances and limited use substances Refer to the Septic Dos and Don ts sec...

Page 7: ...om LEAKY FIXTURES Watch out for and repair leaking fixtures such as a toilet constantly running because leaks add large quantities of water to your wastewater system and negatively affect the drain fi...

Page 8: ...etroleum based products and sawdust should not enter the septic system MEDICATIONS DO NOT FLUSH UNUSED MEDICATIONS DOWN THE DRAIN Please dispose properly by returning unused medication to the pharmacy...

Page 9: ...When the sludge level exceeds the limits set by BioMicrobics see Service Manual the Service Provider will recommend that the FAST system be pumped out by the Septic Tank Pumper The Service Provider s...

Page 10: ...ch as lethal gases and high voltage electricity are associated with the system Introducing harmful or damaging substances into the FAST system may void the warranty ALARMS Your FAST system has an audi...

Page 11: ...of labor and all other expenses resulting from replacement of the defective parts and from installation of parts furnished under this warranty shall be borne by the owner This warranty does not cover...

Page 12: ...ame _____________________________ Designer Phone ___________________________________ Health Official Name _______________________________ Health Official Phone _______________________________ Installe...

Reviews: