54
Programming Devices
Section 3-4
Compatible Programming
Devices
The following Programming Devices can be used.
• Programming Consoles
• CX-Programmer Ver. 1.2 or later (register the PLC model as a CQM1H-
CPU61.)
Note
1.
The Customizable Counter Unit cannot be used with CX-Programmer Ver.
1.1 or earlier.
2.
The SYSMAC-CPT or SYSMAC Support Software cannot be used.
Functions Supported by
Programming Devices
The functions available when using a Programming Device with the Customiz-
able Counter Unit are the same as when using one with a CPU Unit with the
following exceptions.
• PLC Setup functions
• Reading the error log
• PLC clock
• Forced set/reset of the PLC
• Data trace
• Reading the cycle time
• PLC information display
Note
Before using the CX-Programmer, refer to the appendix,
Precautions in Using
the CX-Programmer.
Settings
The following settings are required when using a Programming Device.
Programming Device Connection Switch
You must turn ON the Programming Device connection switch on the front of
the Unit before connecting a Programming Device to the peripheral port. It will
not be possible to connect to the Programming Device if this switch is turned
OFF. (Turn OFF this switch, however, to prevent malfunctions due to opera-
tional errors.)
Unit Setup Area
When connecting a Programming Device to the peripheral port, depending on
the type of Programming Device, the serial communications mode, and com-
munications conditions used, the Unit Setup Area (DM 6650 to DM 6651) set-
tings may or may not be necessary. This is shown in the following table.
Programming Device connection
switch
Programming Device
Connection enabled
(The switch must be turned ON to use a
Programming Device.)
Connection disabled
(Turn OFF the switch to prevent
operational errors.)
Set to ON:
TOOL
ON
OFF
Set to OFF:
TOOL
ON
OFF
Programming Device
Serial
communications
mode (recognized by
Unit)
Communications
conditions
Unit Setup Area
(DM 6650 to
DM 6651)
Setting in CX-
Programmer
Programming Console
(Programming Con-
sole bus)
---
Settings not required
---
CX-Programmer
Peripheral bus
9,600 bps
Settings not required
Set to the same com-
munications condi-
tions.
Other than above
Set in DM 6650 to
DM 6651 (baud rate
only)
Summary of Contents for CS1W-HCA12-V1
Page 2: ......
Page 6: ...vi...
Page 20: ...xx Conformance to EC Directives 7...
Page 38: ...18 Models and System Configurations Section 1 2...
Page 78: ...58 Fail safe Circuits Section 3 5...
Page 138: ...118 AR Area Section 6 4...
Page 204: ...184 Improved Instructions Section 7 14...
Page 222: ...202 Cycle Time Section 8 3...
Page 240: ...220 Troubleshooting Flowcharts Section 9 5...
Page 244: ...224 Precautions when Using the CX Programmer Appendix A...
Page 252: ......
Page 253: ......