95
SR Area
Section 6-3
SR 240
00 to 15
Input Interrupt 0 (IR 00000) Counter
Mode SV
Counter SVs when input interrupts are
used in Counter Mode (0000 to FFFF
Hex).
Note:
When input interrupts are not
used in Counter Mode, these bits can be
used as work bits.
User
SR 241
00 to 15
Input Interrupt 1 (IR 00001) Counter
Mode SV
SR 242
00 to 15
Input Interrupt 2 (IR 00002) Counter
Mode SV
SR 243
00 to 15
Input Interrupt 3 (IR 00003) Counter
Mode SV
SR 244
00 to 15
Input Interrupt 0 (IR 00000) Counter
Mode PV
Counter PVs when input interrupts are
used in Counter Mode (0000 to FFFF
Hex).
Unit
SR 245
00 to 15
Input Interrupt 1 (IR 00001) Counter
Mode PV
SR 246
00 to 15
Input Interrupt 2 (IR 00002) Counter
Mode PV
SR 247
00 to 15
Input Interrupt 3 (IR 00003) Counter
Mode PV
SR 248
00 to 03
Customizable Counter Unit’s unit num-
ber
´
1 (0 to 9; BCD)
The unit number
(00 to 95; BCD) set
with the rotary
switches on the
front of the Unit is
stored here.
Unit
04 to 07
´
10
(0 to 9; BCD)
08 to 15
(Reserved by system.)
---
Address
Bits
Function
Controlled
by
Summary of Contents for CS1W-HCA12-V1
Page 2: ......
Page 6: ...vi...
Page 20: ...xx Conformance to EC Directives 7...
Page 38: ...18 Models and System Configurations Section 1 2...
Page 78: ...58 Fail safe Circuits Section 3 5...
Page 138: ...118 AR Area Section 6 4...
Page 204: ...184 Improved Instructions Section 7 14...
Page 222: ...202 Cycle Time Section 8 3...
Page 240: ...220 Troubleshooting Flowcharts Section 9 5...
Page 244: ...224 Precautions when Using the CX Programmer Appendix A...
Page 252: ......
Page 253: ......