SECTION 3
CJ-series ID Sensor Units
Specifications
General Specifications
General specifications conform to those of SYSMAC CJ-series Special I/O Units.
Performance Specifications
Note 1.
“Rack” indicates either the CPU Rack or an Expansion Rack.
2.
The V680-H01 Antenna can be connected only to the CJ1W-V680C11 ID Sensor Unit.
It cannot be used with the CJ1W-V680C12 ID Sensor Unit.
3.
If using Intelligent I/O Instructions is specified as the data transfer method, up to 2,048 bytes can be
transferred in one scan.
CJ1W-V680C11
CJ1W-V680C12
Unit classification
Special I/O Unit
Influence on CPU Unit's cycle
time
0.15 ms
0.3 ms
Internal current consumption
V680-HA63
@
Amplifier connected: 5 VDC, 260 mA
24 VDC, 130 mA
V680-H01 Antenna connected:
5 VDC, 260 mA
24 VDC, 280 mA
5 VDC, 320 mA max.
24 VDC, 260 mA max.
Dimensions
31 x 90 x 65 mm (W x H x D)
Weight
120 g max.
130 g max.
Mounting location
CJ-series Rack or CJ-series Expansion Rack
(Cannot be mounted to C200H Expansion I/O Racks or SYSMAC BUS Slave Racks.)
No. of Units per Rack
CJ1W-PA205R:
V680-HA63
@
Amplifier connected: 4 per Rack
V680-H01Antenna connected:
2 per Rack
CJ1W-PA202:
V680-HA63
@
Amplifier connected: 2 per Rack
V680-H01Antenna connected:
1per Rack
(See note 1.)
CJ1W-PA205R: 2
CJ1W-PA202: 1
(See note 1.)
Connectable Antennas (See
note 2.)
V680-series Amplifiers (V680-HA63
@
)
V680-series Antennas (V680-H
@@
)
One channel
V680-series Amplifiers (V680-HA63
@
)
V680-series Antennas (V680-H
@@
)
One or two channels
Applicable RF Tags
V680-series RF Tags (V680-D
@@
)
No. of allocated unit numbers
1
2
No. of allocated words
10 words
20 words
Control protocol
Special protocol
Data exchange methods
with CPU Unit
Special I/O Unit Area:
CIO 2000 to CIO 2959
Constant data exchange
of 10 words/Unit
CPU Unit to ID
Sensor Unit
Unit controls, communications
processing specification,
data storage area specification
ID Sensor Unit to
CPU Unit
Unit information, results information,
processing results monitor
Special I/O Unit words in
DM Area: D20000 to
D29599
100 words/Unit
transferred when power
is turned ON or when
restarting the Unit
CPU Unit to ID
Sensor Unit
System Settings, Auto Wait Time
Setting, Write Protection Disable
Setting, Antenna Connection Setting,
Results Monitor Output, Test Setting,
Run/Test Switching Method Setting
Data transfer quantity
2,048 bytes max. (160 bytes/scan) (See note 3.)
2,048 bytes max./channel (160 bytes/scan) (See note 3.)
Operating modes
Run Mode
Test Mode
• Communications tests
• Range level measurements
• Read speed level measurements
• Write speed level measurements
• Noise level measurements
• Communications success rate measurements
Diagnostic functions
(1) CPU watchdog timer
(2) Communications error detection with RF Tag
(3) Antenna power supply error