202
SECTIO
N
8
Sample Pro
g
ramming
RFID System
User's Manual
SECTION 8
Appendices
• Programming Example
When the execution input turns ON, settings are made in the Special I/O Unit Area using the MOV
instruction and the command is executed. Data is read from the memory of RF Tag A and written to the
memory of RF Tag B. When communications with RF Tag B have been completed, the Normal End
Flag (CIO n+7, bit 01) or Error End Flag (CIO n+7, bit 02) is turned ON.
MOV
2771
#0900
MOV
2772
#0020
MOV
2773
#0010
MOV
2776
#0010
2770.00
0010.01
0010.01
2777.01
2777.02
2777.00
0010.01
2777.14
2777.15
Execution input
ID Busy
Waiting for command
execution (work bit)
Test Mode
Unit Busy
Command Execution Bit
Normal end
Specification of command,
communications specifications
Specification of first read address.
Specification of number of
read (write) bytes.
Write data storage location
Waiting for command execution
(work bit)
Error end
Normal End Flag
Error End Flag
Waiting for command
execution (work bit)
Used to time getting
results information.