SECTION 4
I/O Da
ta
Al
loca
ti
ons
SECTION 4
Data Exchange with the CPU Unit
73
RFID System
User's Manual
• Processing Results Monitor Data
Run Mode
Communications Test Mode
Range Level Measurement
When a V680-H01 Antenna is connected, tests other than the communications test cannot be performed. No matter
which test is set, only the RF Tag communications test operation will be performed.
Input
(cont’d)
n+9
n+19
00 to 15 Monitor
Processing
Results Monitor
Run Mode
•
Communications Time
Normal end:
Processing time (1 to 9999 x 10 ms)
Max. error: 10 ms
Error end: “E0” + “Error Code”
Other: “0000”
•
Noise Level
Communications end: “C0” + “00” to “99”
Measurement error: “E0” + “Error Code”
Other: “0000”
Test Mode
Normal end: “Command code” + <Results>
Error end: “E0” + “Error Code”
Other: “0000”
Cleared when the power supply is turned
ON or command execution starts.
Word address
n+9
Bit No.
15 to 12
11 to 08
07 to 04
03 to 00
When the power supply is turned ON or communications
are started
0
0
0
0
At a normal end
Processing time (1 to 9999
×
10 ms) (hex) or Noise level (C0000 to
C099)
At an error end
E
0
Error code
Word address
n+9
Bit No.
15 to 12
11 to 08
07 to 04
03 to 00
When the power supply is turned ON or communications
are started
0
0
0
0
At a normal end
Processing time (1 to 9999
×
10 ms) (hex)
At an error end
E
0
Error code
Word address
n+9
Bit No.
15 to 12
11 to 08
07 to 04
03 to 00
At a normal end
A
0
Range level measurement
results (00 to 06)
At an error end
E
0
Error code
I/O
Word address
Bit No.
Type
Bit name
Description
Antenna 1 of
CS1W-V680C11,
CS1W-V680C12,
CJ1W-V680C11,
or
CJ1W-V680C12
Antenna 2 of
CS1W-V680C12
or
CJ1W-V680C12
Summary of Contents for CJ1W-V680C11