Features and System Configuration
Differences between Version 1.2 and Pre-Version 1.2
The following functions have been added to version 1.2 in comparison to pre-version 1.2. Functions are
upwardly compatible, so pre-version 1.2 can be replaced with version 1.2.
CA1D Mode Setting Added for RF Tag Memory
If you are using a V680-CA1D/-CA2D ID Controller, always set the RF Tag memory setting to CA1D
Mode. Setting the RF Tag memory setting to CA1D Mode enables reading and writing Heat-resistant
RF Tags (V680-D1KP58HTN and V680-D1KP58HT) that were written by the V680-CA1D/-CA2D.
New Data Transfer Setting
In addition to cyclically transferring 160 bytes/scan, Intelligent I/O Instructions can now be used to
transfer up to 2,048 bytes in one scan.
Parameters Added to Data Memory Allocation
DM Area allocations now include a RF Tag memory setting and data transfer setting.
Refer to
DM Area Allocations and Contents
on page 65 for details on the DM Area.
A label on the side of the ID Sensor Unit shows the version for Units with version 1.2 or newer.
A different memory map may be used when reading or writing Heat-resistant RF Tags that were written by the V680-
CA1D/-CA2D from a Reader/Writer that is manufactured by a company other than OMRON. Refer to
Operation When
RF Tag Memory Setting Is Set to Standard Mode
in this section.