SECTIO
N
8
Sample Pro
g
ramming
SECTION 8
Appendices
199
RFID System
User's Manual
• Timing Chart (CIO n = CIO 2000 + (10 x 55) = CIO 2550)
• To confirm the execution results from the user program, use the ON status of the Normal End Flag or
Error End Flag. These flags show the Unit status.
• Do not turn ON the Command Execution Bit during command execution (i.e., while the ID Busy Flag
is ON). It will be ignored.
• Execute the IOWR instruction before executing the write command.
0000
0000
IO
W
R exec
u
tion re
qu
est
Res
u
lts Information
CIO n+
8
Command Exec
u
tion Bit
CIO n,
b
it 00
Command
CIO n+1 to n+4
N
ormal End
CIO n+7,
b
it 01
ID B
u
sy
Data storage area
Error End
CIO n+7,
b
it 02
CIO n+7,
b
it 00
W
rite
W
rite
1 scan
N
ormal end
W
rite data
Comm
u
nications
processing
W
aiting for
RF Tag
1 scan
Missing error