SE
C
T
IO
N
2
Ope
rat
in
g Pr
oce
dure
SECTION 2
CS-series ID Sensor Units
37
RFID System
User's Manual
Ladder Programming
Set the Command, Communications Specification, Read Data Storage Order, First RF Tag Read Address,
Number of Bytes to Read, and Read Data Storage Destination in CIO n+1 to CIO n+6 allocated in the Special
I/O Unit Area (here, CIO 2011 to CIO 2016).
First word allocated to Unit in CIO Area: CIO 2000 + 10 × 0 = CIO 2000
*: Always 0 when DM Area is specified.
---: Ignored.
Word
address
Contents
Meaning
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
CIO 2001 00
0
0
Command
Communications
specification
Data order
CIO 2002 00
10
First read address
CIO 2003 00
0A
Number of read bytes
CIO 2004 10
00
Read data storage location (rightmost 4 digits)
CIO 2005 0
0
00
Data storage area
Bank specification*
Read data storage location (leftmost 2 digits)
CIO 2006 00
00
---
Peripheral port
Programming Console
MOV
2001
#0000
MOV
2002
#0010
Execution input
MOV
2003
#000A
MOVL
2004
#00001000
2000.00
0010.01
0010.01
2007.01
2007.02
2007.00
0010.01
2000.02
0010.02
0010.02
2007.00
ID Busy
Test Mode
Unit Busy
2007.14
2007.15
Waiting for
command
execution
(work bit)
Specification of command,
communications specification,
and read data storage order.
Specification of first read address.
Read data storage location
Specification of number of read bytes.
Waiting for command execution
(work bit)
Command Execution Bit
Abort Bit
Waiting for Abort
(work bit)
Normal end
Error end
Used to time getting read data.
Used to time getting results information.
Error End Flag
Normal End Flag
Waiting for abort
(work bit)
ID Busy
Abort input
Waiting for command
execution (work bit)
Summary of Contents for CJ1W-V680C11
Page 213: ......