SECTION 5
Parameter
Settin
gs
in DM
Area
SECTION 5
ID Sensor Unit Functions
93
RFID System
User's Manual
Parameter Settings in DM Area
The following parameter settings can be adjusted to the user application to optimize the performance and
reliability of the ID Sensor Unit.
• System Settings
• Auto Wait Time Setting
• Write Protection Disable Setting
• Antenna Connection Setting
• Results Monitor Output Setting
• Test Settings
• Run/Test Switching Method Setting
Although the default settings can be used for most applications without any problems, the parameters can be
changed to optimize the system.
System Settings
UID Addition Setting
These settings are used to set whether or not a UID will be added to the read command response.
Note:
If adding the UID is specified, the UID (8 bytes) will be appended to the front of the read
response data.
If using Intelligent I/O Instructions is specified as the data transfer method, set the IORD service control information
area address information in D00004 to D00007 to 1. The first four words of data will be the UID data.
Test Mode Disable Setting
This setting can be used to disable entering Test Mode using the test switch on the front panel of the ID
Sensor Unit. The test switch can be disabled to prevent accidentally entering Test Mode.
DM Area address
Bit No.
Description
Default
Antenna 1 of
CS1W-V680C11,
CS1W-V680C12,
CJ1W-V680C11, or
CJ1W-V680C12
Antenna 2 of
CS1W-V680C12 or
CJ1W-V680C12
m
m+100
12 to 15
0
UID not added
0
(Not added)
1
UID added
DM Area address
Bit No.
Description
Default
Antenna 1 of
CS1W-V680C11,
CS1W-V680C12,
CJ1W-V680C11, or
CJ1W-V680C12
Antenna 2 of
CS1W-V680C12 or
CJ1W-V680C12
m
m+100
08 to 11
0
Test switch enabled.
0
(Enabled)
1
Test switch disabled (always Run Mode).