SECTION 3
Ope
rat
ing Proce
dure
SECTION 3
CJ-series ID Sensor Units
49
RFID System
User's Manual
Operating Procedure Example
The following is an operating procedure example for the following conditions.
Reading 10 Bytes of Data from RF Tag Address 0010 Using a Trigger.
• Special I/O Unit Area Settings
Unit number: 00
Command: Read
Communications specification: Trigger
Read data storage order: Leftmost
→
Rightmost
First RF Tag read address: 0010 hex
Number of RF Tag read bytes: 10 bytes
Read data storage destination: D1000 to D1004
15 00
D1000 01 02
D1001 03 04
D1002
05 06
D1003
07 0
8
D1004
09 0A
RF Tag
Address (hex)
7 0
0010 0
1
0011 0
2
0012 0
3
0013 0
4
0014 0
5
0015
0 6
0016 0
7
0017 0
8
001
8
0
9
0019 0
A
CJ1
W
-
V
6
8
0C11
Comm
u
ni-
cations
Read data
Read command
→
: Read data storage order
CJ-series CPU Unit
Special I/O
Unit Area