background image

 
 

B5U033000E 

 

Page 1 of 54

 

 

UHF

 

RFID System

 

 
 

 

 
 

 
 

M30 Form Factor

 

BLUEBOX ADVANT UHF

 

 

 
 

 

 

 

Summary of Contents for BLUEBOX ADVANT UHF

Page 1: ...B5U033000E Page 1 of 54 UHF RFID System M30 Form Factor BLUEBOX ADVANT UHF...

Page 2: ...d without previous notice Composition of the information in this manual has been done to the best of our knowledge IDTRONIC does not guarantee the correctness and completeness of the details given in...

Page 3: ...ty by the manufacturer The liability prescriptions of the manufacturer in the issue valid at the time of purchase are valid for the device The manufacturer shall not be held legally responsible for in...

Page 4: ...manual is valid as of firmware version Order Number Hardware Version Firmware Version 5227U 1 1 54C 5227U 2 2 54C Items 5227U with hardware version 1 and firmware version 1 xx are obsolete items and n...

Page 5: ...gement 30 3 2 4 RF Tuning 33 4 Installation 37 4 1 General Instructions 37 4 2 Notes on Tag Mounting 37 4 3 Avoiding Interference 37 4 4 Mechanical Design 38 4 5 Fixing 38 4 6 Mounting Distances 39 4...

Page 6: ...e BLUEBOX communicates with a host system typically a PC or a PLC through CAN bus communication interface with CANopen protocol item 5227U and acts as a joint through a set of commands between the hos...

Page 7: ...Antenna Integrated Reading Distance 40cm1 Supported Transponders ISO 18000 632 EPC Class 1 Gen 2 V2 Communication Interface CAN bus with CANopen protocol Status Display 1 bicolor LED Connections 5 po...

Page 8: ...age 8 of 54 2 3 Environmental Conditions This section provides details on the environmental conditions of the BLUEBOX Operating Temperature 20 C 55 C Storage Temperature 40 C 85 C Humidity Up to 95 no...

Page 9: ...When a tag is identified the BLUEBOX verifies if it belongs to the list of read tags If the tag do not belong to the list it is defined as new its code will be inserted in the queue a filter time ass...

Page 10: ...by the antenna at a given frequency to check the presence of external RF sources The BLUEBOX integrates a reconfigurable RF carrier leakage canceler feature which allows the usage of the reader in man...

Page 11: ...e transponder type information in the tag s code Disabled Enabled Disabled Continuous Mode Continuous mode Disabled Enabled Enabled Sub Index Parameter Description 01h Filter Time Reading and tag queu...

Page 12: ...ault Value 02h Save Object Yes Sub Index 01h Description Filter time Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See value definition Default Value 01h Save Object Yes Sub Index 02h Descr...

Page 13: ...within the record The number of valid objects entries shall be the number of the general configuration parameters Its value is 08h Sub index 01h to 08h contains a configuration parameter An attempt to...

Page 14: ...tion with the correct RF settings and are solely responsible for any fines and other damages due to incorrect or non compliant country region settings 0 00 0 99 seconds 0 99 seconds 0 RF Channel Pause...

Page 15: ...Activation A byte whose bits are dedicated to disable 0 value or enable 1 value the antennas to use Bit 7 Not used Bit 6 Not used Bit 5 Not used Bit 4 Not used Bit 3 Not used Bit 2 Not used Bit 1 Not...

Page 16: ...pion Index 2201h Name RF configuration Object Code RECORD Data Type RF configuration record Entry Description Sub Index 00h Description Number of parameters Data Type UNSIGNED8 Access RO PDO Mapping N...

Page 17: ...lt Value 14h Save Object Yes Sub Index 03h Description RF input sensitivity Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See value definition Default Value 4Ch Save Object Yes Sub Index 04...

Page 18: ...06h Description RF channel allocation time Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See value definition Default Value 00h Save Object Yes Sub Index 07h Description RF channel pause ti...

Page 19: ...BLUEBOX user manual for value definition details Parameter Description Range Default Inventory Mode How the reader does an inventory in continuous mode Fast Multi Tag Fast Single Tag Standard Multi T...

Page 20: ...om None ReadAfterDete ct Password The password to be used to access to tag s memory in ReadAfterDetect mode Inventory Mode Standard Single Multi Tag with Custom Info Use a 0 password if the access pas...

Page 21: ...tivation parameters Bit 7 Not used Bit 6 Search mode how the reader singulates tags in continuous mode o 0b Dual Target the reader singulates tags in both A and B states o 1b Single Target the reader...

Page 22: ...get 02h R T Link Frequency R T link frequency 0x00 40 kHz 0x02 160 kHz 0x04 256 kHz 0x05 320 kHz 0x06 640 kHz 03h R T Bit Coding R T bit coding 0x00 FM0 0x01 Miller 2 0x02 Milller 4 0x03 Miller 8 Note...

Page 23: ...ReadAfterDetect mode Inventory Mode Standard Single Multi Tag with Custom Info Use a 0 password if the access password is not requested 0Eh ReadAfterDete ct Bank The tag s memory bank to access in Re...

Page 24: ...0x00 Disabled 0x01 Enabled 13h AFI The AFI value Object Descritpion Index 2202h Name EPC Class 1 Generation 2 configuration Object Code RECORD Data Type EPC Class 1 Generation 2 configuration record E...

Page 25: ...GNED8 Access RW PDO Mapping No Value Range See value definition Default Value 02h Save Object Yes Sub Index 03h Description R T bit coding Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See...

Page 26: ...ue Range See value definition Default Value 03h Save Object Yes Sub Index 06h Description Q initial Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See value definition Default Value 00h Save...

Page 27: ...e definition Default Value 03h Save Object Yes Sub Index 09h Description Inventory cycles Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See value definition Default Value 03h Save Object Ye...

Page 28: ...alue 00h Save Object Yes Sub Index 0Ch Description EPC size Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See value definition Default Value 00h Save Object Yes Sub Index 0Dh Description Re...

Page 29: ...Index 0Fh Description ReadAfterDetect address Data Type UNSIGNED32 Access RW PDO Mapping No Value Range UNSIGNED32 Default Value 00000000h Save Object Yes Sub Index 10h Description ReadAfterDetect le...

Page 30: ...ue Range See value definition Default Value 00h Save Object Yes Sub Index 13h Description AFI Data Type UNSIGNED8 Access RW PDO Mapping No Value Range UNSIGNED8 Default Value 00h Save Object Yes 3 2 3...

Page 31: ...p The power step in dynamic power management mode activated Note that this parameter become effective only after a reboot of the reader 1 5 dB 10 500 mW 1 dB Time Step The time step in dynamic power m...

Page 32: ...e UNSIGNED8 Access RO PDO Mapping No Value Range 03h Default Value 03h Save Object Yes Sub Index 01h Description Mode Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See value definition Defa...

Page 33: ...The dynamic power management parameters are managed through the OD 2204h Value Definition Sub index 00h contains the number of valid object entries within the record The number of valid objects entrie...

Page 34: ...Steps The maximum runtime RF tune steps 0 to disable the runtime RF tuning 02h Max Tune Frequency Hops The maximum RF frequency hops on the same RF frequency before RF tuning 03h Min Tune Frequency Ho...

Page 35: ...value definition Default Value 64h Save Object Yes Sub Index 02h Description Max Tune Frequency Hops Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See value definition Default Value 0Fh Sa...

Page 36: ...B5U033000E Page 36 of 54 Save Object Yes Sub Index 04h Description Tune Hysteresis Index Data Type UNSIGNED8 Access RW PDO Mapping No Value Range See value definition Default Value 1Eh Save Object Yes...

Page 37: ...upply as defined in electrical connections section The boot sequence begins in either case when power is supplied to the device This sequence typically completes within 5 seconds After the boot sequen...

Page 38: ...B5U033000E Page 38 of 54 Observe the notes on installation when several RFID UHF devices are operated simultaneously 4 4 Mechanical Design 4 5 Fixing Fix the device using the supplied nuts M30...

Page 39: ...ance Front B Reading and writing at 100 transmitter power simultaneous operation 6 0mt 10 0mt Reading and writing at 100 transmitter power alternating operation 0 3mt 0 3mt 4 7 Positioning of the Tags...

Page 40: ...firmly screwed The device can be damaged by insufficiently tightened M12 connectors Screw the M12 connector to the device applying 1 to 1 5 Nm 5 1 Item 5227U Connect the BLUEBOX to the voltage supply...

Page 41: ...potential free from external voltage Hereinafter a cross reference table between connection pin number and the color of the wires of a CAN bus 5 poles cable with 5 poles M12 A coded female connector a...

Page 42: ...off phase approximately 1000 ms Double flash That shall indicate a sequence of two short flashes approximately 200 ms separated by an off phase approximately 200 ms The sequence is finished by a long...

Page 43: ...shes alternately with green LED Configuration or hardware error Blinking According to the current operating status CAN bus warning limit reached Flashes single flash According to the current operating...

Page 44: ...factors like antenna size transponder size transponder IC type orientation between transponder and reader antenna position of the transponder versus the reader antenna noise environment metallic envi...

Page 45: ...maintenance and repair measures are necessary The device must only be repaired by the manufacturer After use dispose of the device in an environmentally friendly way in accordance with the applicable...

Page 46: ...ation to which conformity is declared Safety of Information Technology Equipment o EN 62368 1 2014 AC 2015 Limitation of human exposure to electromagnetic fields from devices operating in the frequenc...

Page 47: ...B5U033000E Page 47 of 54 10 Mechanical Drawings All the dimensions are in mm...

Page 48: ...nges and corrections in the configuration parameters Moved the plans of frequencies from RF configuration section to regions of operations appendix Moved the power requirements from antennas section t...

Page 49: ...B5U033000E Page 49 of 54 Date Revision Description Added the regulatory compliance section...

Page 50: ...errogators a means to minimize the overall length of transmission commensurate with the application This may include the provision of trigger mechanisms within interrogators to initiate transmissions...

Page 51: ...RF Channel Frequency MHz 1 902 75 2 903 25 3 903 75 49 926 75 50 927 25 Other RF channels and single channel selection are present only for test purposes and should not be used in normal operation FC...

Page 52: ...e FCC North American spectrum 902 928 MHz with specific frequency and channel usage dictated by regulations of each country Frequency hopping spread spectrum FHSS is used No listen before talk is perf...

Page 53: ...75 50 927 25 Other RF channels and single channel selection are present only for test purposes and should not be used in normal operation Brazil regulations describe the radiating power limits in rela...

Page 54: ...r of allowance of 30dBm at the antenna connector is allowed The maximum BLUEBOX RF output power is defined as PC max PEIRP max GIC 2 15 5 15 CL Where PC max Maximum RF output power in dBm PERP max Max...