SECTION 1
Features and System Configuration
23
RFID System
User's Manual
Mounting Restrictions
CS-series PLCs
CS-series ID Sensor Units are classified as CS-series Special I/O Units.
• These Units can be mounted to a CS-series CPU Rack or CS-series Expansion Rack.
• The number of Units per CPU Rack or Expansion Rack depends on the maximum supply current of
the Power Supply Unit and current consumption of other Units on the Rack.
The following table lists the maximum number of Units per Rack when only ID Sensor Units are
mounted.
The V680-H01 Antenna can be connected to only the One-channel ID Sensor Unit (CS1W-V680C11).
It cannot be connected to the Two-channels ID Sensor Unit (CS1W-V680C12).
CJ-series PLCs
CJ-series ID Sensor Units are classified as CJ-series Special I/O Units.
• These Units can be mounted to a CJ-series CPU Rack or CJ-series Expansion Rack.
• The number of Units per CPU Rack or Expansion Rack depends on the maximum supply current of
the Power Supply Unit and current consumption of other Units on the Rack.
The following table lists the maximum number of Units per Rack when only ID Sensor Units are
mounted.
The V680-H01 Antenna can be connected to only the One-channel ID Sensor Unit (CJ1W-V680C11).
It cannot be connected to the Two-channels ID Sensor Unit (CJ1W-V680C12).
The I/O words allocated to Special I/O Units are determined by the setting of the unit number switches on the front of the Unit.
They are not affected by the slots (positions) in which the Units are mounted.
Power Supply Unit
CS1W-V680C11
CS1W-V680C12
V680-HA63
@
Amplifier
connected
V680-H01 Antenna connected
V680-HA63
@
Amplifier
connected
C200HW-PA204
C200HW-PA204S
C200HW-PA204R
C200HW-PD204
5
2
10
C200HW-PA209R
9
4
10
Power Supply Unit
CJ1W-V680C11
CJ1W-V680C12
V680-HA63
@
Amplifier
connected
V680-H01Antenna connected
V680-HA63
@
Amplifier
connected
CJ1W-PA205R
4
2
2
CJ1W-PA202
2
1
1