SECTION 5
Parameter
Settin
gs
in DM
Area
SECTION 5
ID Sensor Unit Functions
95
RFID System
User's Manual
Auto Wait Time Setting
If a normal response is not received in communications with an RF Tag when the RF Tag has been
detected, retry processing will be performed to resend the same command. Retry processing is
performed until the Auto Wait Time has expired while the ID Sensor Unit is waiting for an RF Tag. The
RF Tag wait status begins for a single auto specification, when command execution is started. From
the second RF Tag for a repeat auto specification, it begins when communications with the previous
RF Tag have been completed.
• First word allocated to Unit in DM Area: m = 100
×
Unit number
After setting DM Area data with the Support Software, reset the power supply to the PLC or turn ON the Special I/O Unit
Restart Bit. The DM Area settings will be transferred to the ID Sensor Unit when the power supply turns ON or when the
Special I/O Unit Restart Bit is turned ON.
Write Protection Disable Setting
The write protection disable setting can be used to disable the write protection settings in RF Tags.
First word allocated to Unit in DM Area: m = 100
×
Unit number
After setting DM Area data with the Support Software, reset the power supply to the PLC or turn ON the Special I/O Unit
Restart Bit. The DM Area settings will be transferred to the ID Sensor Unit when the power supply turns ON or when the
Special I/O Unit Restart Bit is turned ON.
DM Area address
Bit No.
Type
Description
Default
Antenna 1 of
CS1W-V680C11,
CS1W-V680C12,
CJ1W-V680C11, or
CJ1W-V680C12
Antenna 2 of
CS1W-V680C12 or
CJ1W-V680C12
m+1
m+101
00 to 15
0000 to 9999
1 to 9999
×
0.1 s
0: Infinite (Time not monitored)
0
(Infinite)
DM Area address
Bit No.
Description
Default
Antenna 1 of
CS1W-V680C11,
CS1W-V680C12,
CJ1W-V680C11,
or CJ1W-V680C12
Antenna 2 of
CS1W-V680C12
or CJ1W-V680C12
m+2
m+102
00 to 07
00
Write protection enabled using V680 method
00 (Write
protection
enabled using
V680 method)
01
Write protection disabled.
02
Write protection enabled using V600 method
Res
u
lts
Comm. A
N
ormal End Flag
Error End Flag
Comm
u
nications
w
ith
RF Tag
RF Tag mo
v
ement
RF Tag A
W
aiting for RF Tag
W
aiting for RF Tag,
A
u
to
W
ait Time exceeded.
Command Exec
u
tion Bit
ID B
u
sy Flag
RF Tag B (missing)
RF Tag Missing Error
Res
u
lts
Summary of Contents for CJ1W-V680C11
Page 213: ......