SECTION 4
Out
lin
e of Dat
a
Exch
ange
SECTION 4
Data Exchange with the CPU Unit
63
RFID System
User's Manual
Unit Number Setting
The words allocated to the ID Sensor Unit in the Special I/O Unit Area and in the DM Area are
determined by the unit number setting on the Unit’s front panel.
• If the same unit number is set for more than one Special I/O Unit, a fatal error (No. duplication error on CX-Programmer or Unit
Number Duplication on Programming Console), and the PLC will not operate.
• When a Two-channels ID Sensor Unit (CS1W-V680C12 or CJ1W-V680C12) is used, two unit numbers are allocated.
Switch
No.
Unit
No.
CS1W-V680C11/
CJ1W-V680C11
CS1W-V680C12/
CJ1W-V680C12
Words allocated in
Special I/O Unit Area
Words allocated
in DM Area
Words allocated in
Special I/O Unit Area
Words allocated
in DM Area
0
Unit 0
CIO 2000 to CIO 2009 D20000 to D20099 CIO 2000 to CIO 2019 D20000 to D20199
1
Unit 1
CIO 2010 to CIO 2019 D20100 to D20199 CIO 2010 to CIO 2029 D20100 to D20299
:
:
:
:
:
:
94
Unit 94
CIO 2940 to CIO 2949 D29400 to D29499 CIO 2940 to CIO 2959 D29400 to D29599
95
Unit 95
CIO 2950 to CIO 2959 D29500 to D29599
(Cannot be set)
0
1
2
3 4 5 6
7
8
9
0
1
2
3 4 5 6
7
8
9
V6
80
C1
2
RU
N
ER
C
HE
AD
1
T/R
NO
RM
/E
RR
ER
P
ER
H
HE
AD
2
T/R
NO
RM
/E
RR
TE
ST
ON
HE
AD
1
HE
AD
2
DC
24
V
IN
PU
T
+
-
CS1W-V680C11/C12
0
1 2 3
4
5
6
7
8
9
0
1 2 3
4
5
6
7
8
9
CJ1W-V680C11/C12